Icom IC-F8101 Instruction Manual - Page 54

ALE Set mode, Decay Time, BER Threshold, Golay Threshold, Silent, Call Retry, Setmode

Page 54 highlights

5 MENU SCREEN DDSetmode  ALE Set mode Decay Time Set the decay time for the Auto Sounding function to between 1 and 8 hours. BER Threshold Set the Bit Error Ratio (BER) threshold level to between 0 and 48 bits for ALE communication quality. One unit consists of 48 bits of data. Golay Threshold Set the Golay threshold level to between 0 and 3 bits for ALE communication quality. The Golay consists of 12 bits of original data and 12 bits of correction data. Error Threshold Set the Error threshold level to between 0 and 4 for ALE communication quality. When errors detected by BER threshold or Golay threshold are over this setting, communication is not possible. Silent Set the ALE Silent mode to ON or OFF. When set to OFF, the transceiver automatically answers back if your station ID is called. When set to ON, the transceiver ignores the call. Call Retry Set the retry times to between 0 (OFF) and 10 when the called station does not answer back. 48 (Default: 1 hour) (Default: 12) (Default: 2) (Default: 0) (Default: OFF) (Default: 1)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

48
5
MENU SCREEN
ALE Set mode
Decay Time
(Default: 1 hour)
Set the decay time for the Auto Sounding function to
between 1 and 8 hours.
BER Threshold
(Default: 12)
Set the Bit Error Ratio (BER) threshold level to be-
tween 0 and 48 bits for ALE communication quality.
One unit consists of 48 bits of data.
Golay Threshold
(Default: 2)
Set the Golay threshold level to between 0 and 3 bits
for ALE communication quality.
The Golay consists of 12 bits of original data and 12
bits of correction data.
Error Threshold
(Default: 0)
Set the Error threshold level to between 0 and 4 for
ALE communication quality.
When errors detected by BER threshold or Golay
threshold are over this setting, communication is not
possible.
Silent
(Default: OFF)
Set the ALE Silent mode to ON or OFF.
When set to OFF, the transceiver automatically an-
swers back if your station ID is called. When set to
ON, the transceiver ignores the call.
Call Retry
(Default: 1)
Set the retry times to between 0 (OFF) and 10 when
the called station does not answer back.
Setmode
D