Icom IC-R75 Instruction Manual - Page 22

Filter selection

Page 22 highlights

5 RECEIVE FUNCTIONS ■ Filter selection The filter selection switches the IF passband width as shown in the table at right. The filter selection is automatically memorized in each mode. q Select the desired mode with the mode switches. w P ush [FIL] one or more times to select the desired filter combination. • ã or ç does not appear while in normal IF filter. • ç appears when wide IF filters are selected. • ã appears when narrow IF filters are selected. When an optional filter is installed, set the optional filter in filter set mode. Optional filters are not selected by default. IF 9 MHz 455 kHz Filter FL-100 FL-101 FL-103 FL-223 FL-232 FL-52A FL-53A FL-96 FL-222 FL-257 Passband Recommended width selectivity 500 Hz/-6 dB CW-N, RTTY-N 250 Hz/-6 dB CW-N 2.8 kHz/-6 dB SSB-W 1.9 kHz/-6 dB SSB-N 350 Hz/-6 dB CW-N, RTTY-N 500 Hz/-6 dB CW-N, RTTY-N 250 Hz/-6 dB CW-N 2.8 kHz/-6 dB SSB-W 1.8 kHz/-6 dB SSB-N 3.3 kHz/-6 dB SSB-W • Filter construction 2nd IF signal 9 MHz IF filter FL-23 (15 kHz) FL-272 (2.4 kHz) FL-103 (2.8 kHz) FL-223 (1.9 kHz) FL-100 (500 Hz) FL-232 (350 Hz) FL-101 (250 Hz) optional Mixer 455 kHz IF filter CFWS450E (15 kHz) CFWS450HT (6 kHz) FL-65 (2.4 kHz) FL-257 (3.3 kHz) FL-96 (2.8 kHz) FL-222 (1.8 kHz) FL-52A (500 Hz) FL-53A (250 Hz) optional 3rd IF signal 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

18
5
RECEIVE FUNCTIONS
Filter selection
The filter selection switches the IF passband width
as shown in the table at right.
The filter selection is automatically memorized in
each mode.
q
Select the desired mode with the mode switches.
w
Push [FIL] one or more times to select the desired
filter combination.
ã
or
ç
does not appear while in normal IF filter.
ç
appears when wide IF filters are selected.
ã
appears when narrow IF filters are selected.
When an optional filter is installed, set the optional
filter in filter set mode. Optional filters are not
selected by default.
• Filter construction
CFWS450E (15 kHz)
CFWS450HT (6 kHz)
FL-65 (2.4 kHz)
FL-257 (3.3 kHz)
FL-96 (2.8 kHz)
FL-222 (1.8 kHz)
FL-52A (500 Hz)
FL-53A (250 Hz)
optional
FL-23 (15 kHz)
FL-272 (2.4 kHz)
FL-103 (2.8 kHz)
FL-223 (1.9 kHz)
FL-100 (500 Hz)
FL-232 (350 Hz)
FL-101 (250 Hz)
optional
Mixer
2nd IF signal
3rd IF signal
9 MHz IF filter
455 kHz IF filter
IF
Filter
Passband
width
Recommended
selectivity
9 MHz
FL-100
500 Hz/–6 dB
CW-N, RTTY-N
FL-101
250 Hz/–6 dB
FL-103
2.8 kHz/–6 dB
SSB-W
CW-N
FL-223
1.9 kHz/–6 dB
SSB-N
455 kHz
FL-52A
500 Hz/–6 dB
CW-N, RTTY-N
FL-53A
250 Hz/–6 dB
CW-N
FL-96
2.8 kHz/–6 dB
SSB-W
FL-232
350 Hz/–6 dB
CW-N, RTTY-N
FL-222
1.8 kHz/–6 dB
SSB-N
FL-257
3.3 kHz/–6 dB
SSB-W