14 CONTROL COMMAND ■ Remote jack (CI-V) information • CI-V connection example The receiver can be connected through an optional CT-17 ci-v level converter to a PC equipped with an RS-232C port. The Icom Communications Interface-V (CI-V) controls the following functions of the receiver. IC-R75 9-15 V DC Up to 4 Icom CI-V transceivers or receivers can be connected to a PC equipped with an RS-232C port. See p. 32 for setting the CI-V condition using set mode. ct-17 PC • Data format The CI-V system can be operated using the following data formats. Data formats differ according to command numbers. A data area or sub command is added for some commands. mini-plug cable CONTROLLER TO IC-R75 q wert y u FE FE 5A E0 Cn Sc Data area FD OK MESSAGE TO CONTROLLER FE FE E0 5A FB FD Preamble code (fixed) Receiver's default address Controller's default address Command number (see table at right) Sub command number (see table at right) BCD code data for frequency or memory number entry End of message code (fixed) Preamble code (fixed) Controller's default address Receiver's default address OK code (fixed) End of message code (fixed) IC-R75 TO CONTROLLER q wert y u FE FE E0 5A Cn Sc Data area FD NG MESSAGE TO CONTROLLER FE FE E0 5A FA FD Preamble code (fixed) Controller's default address Receiver's default address Command number (see table at right) Sub command number (see table at right) BCD code data for frequency or memory number entry End of message code (fixed) Preamble code (fixed) Controller's default address Receiver's default address NG code (fixed) End of message code (fixed) 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

14
40
CONTROL COMMAND
• CI-V connection example
The receiver can be connected through an optional
CT-17
CI-V LEVEL CONVERTER
to a PC equipped with an
RS-232C port. The Icom Communications Interface-V
(CI-V) controls the following functions of the receiver.
Up to 4 Icom CI-V transceivers or receivers can be
connected to a PC equipped with an RS-232C port.
See p. 32 for setting the CI-V condition using set
mode.
• Data format
The CI-V system can be operated using the following
data formats. Data formats differ according to
command numbers. A data area or sub command is
added for some commands.
CONTROLLER TO IC-R75
FE
FE
FE
5A
E0
Cn
Sc
Data area
FD
Preamble code (fixed)
Receiver’s default address
Controller’s default address
Command number
(see table at right)
Sub command number
(see table at right)
BCD code data for frequency or
memory number entry
End of message code (fixed)
OK MESSAGE TO CONTROLLER
FE FE E0 5A FB FD
Preamble code (fixed)
Controller’s default address
Receiver’s default address
OK code (fixed)
End of message code (fixed)
NG MESSAGE TO CONTROLLER
FE FE E0 5A FA FD
Preamble code (fixed)
Controller’s default address
Receiver’s default address
NG code (fixed)
End of message code (fixed)
IC-R75 TO CONTROLLER
FE
E0
5A
Cn
Sc
Data area
FD
Preamble code (fixed)
Controller’s default address
Receiver’s default address
Command number