Icom IC-R75 Instruction Manual - Page 31

Priority watch operation, Auto memory write scan

Page 31 highlights

SCANS 7 ■ Priority watch operation Priority watch checks for signals on a frequency every 5 sec. while operating on a VFO frequency. q Select memory mode with [V/M]. w S elect the desired memor y channel to be watched with [UP Y] or [Z DN]. e Select VFO mode. r S et [RF/SQL] closed. • If the [RF/SQL] control function is set as RF control, the squelch always opens. See pgs. 14, 30 for details. t Push [SCAN] for 2 sec. to start priority watch. • "SCAN" appears. USB ANT 1 AGC S1 3 5 7 9 20 40 60dB VFO SCAN y W hen a signal is received on a watch channel, the function display shows the watch channel and "SCAN" blinks. USB R X ANT 1 AGC S1 3 5 7 9 20 40 60dB SCAN MEMO u To cancel the watch, push [SCAN]. ■ Auto memory write scan Auto memory write scan operates in the same way as programmed scan. However, when a signal is received, the received frequency is automatically written into memory channels (80 to 99). When the auto memory write scan starts, the previously written memory channels (80 to 99) are cleared. 80 14.456.00 81 14.567.00 82 14.678.00 83 14.890.00 84 14.050.00 98 99 q S elect VFO mode with [V/M]. w Select the desired operating mode. • The operating mode can also be changed while scanning. e Set [RF/SQL] closed. • If the [RF/SQL] control function is set as RF control, the squelch always opens. See pgs. 14, 30 for details. r Push [SCAN] to start the programmed scan. • "SCAN" appears while scanning. • If the same frequencies are programmed into the scan edge memory channel P1 and P2, programmed scan does not start. t Push [MW] to start the auto memory write scan. • "80" blinks when auto memory write scan starts. USB R X ANT 1 AGC BLANK S1 3 5 7 9 20 40 60dB VFO SCAN y W hen the scan detects a signal, the frequency is programmed into a memory channel (80 to 99), starting from channel 80. u To cancel the scan, push [SCAN]. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

27
7
SCANS
Priority watch operation
Priority watch checks for signals on a frequency
every 5 sec. while operating on a VFO frequency.
q
Select memory mode with [V/M].
w
Select the desired memory channel to be
watched with [UP
Y
] or [
Z
DN].
e
Select VFO mode.
r
Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control,
the squelch always opens. See pgs. 14, 30 for details.
t
Push [SCAN] for 2 sec. to start priority watch.
• “SCAN” appears.
y
When a signal is received on a watch channel,
the function display shows the watch channel and
“SCAN” blinks.
u
To cancel the watch, push [SCAN].
USB
S1
3
5
7
9
20
40
60
dB
AGC
ANT 1
SCAN
VFO
USB
S1
3
5
7
9
20
40
60
dB
AGC
ANT 1
SCAN
R X
MEMO
Auto memory write scan
Auto memory write scan operates in the same way
as programmed scan. However, when a signal is
received, the received frequency is automatically
written into memory channels (80 to 99).
When the auto memory write scan starts, the
previously written memory channels (80 to 99) are
cleared.
q
Select VFO mode with [V/M].
w
Select the desired operating mode.
• The operating mode can also be changed while
scanning.
e
Set [RF/SQL] closed.
• If the [RF/SQL] control function is set as RF control,
the squelch always opens. See pgs. 14, 30 for details.
r
Push [SCAN] to start the programmed scan.
• “SCAN” appears while scanning.
• If the same frequencies are programmed into the scan
edge memory channel P1 and P2, programmed scan
does not start.
t
Push [MW] to start the auto memory write scan.
• “80” blinks when auto memory write scan starts.
y
When the scan detects a signal, the frequency is
programmed into a memory channel (80 to 99),
starting from channel 80.
u
To cancel the scan, push [SCAN].
80
81
82
83
84
98
99
14.456.00
14.567.00
14.678.00
14.890.00
14.050.00
--------------
--------------
USB
R X
S1
3
5
7
9
20
40
60
dB
AGC
ANT 1
SCAN
VFO
BLANK
BLANK