Intel E5310 Specification Update - Page 13

Errata Sheet 4 of 6 - xeon 1 6

Page 13 highlights

Errata (Sheet 4 of 6) Number Steppings B-3 G-0 AJ73 X X AJ74 X X AJ75 X X AJ76 X AJ77 X X AJ78 X AJ79 X X AJ80 X X AJ81 X X AJ82 AJ83 X X AJ84 AJ85 X AJ86 X X AJ87 X X AJ88 X X AJ89 X X AJ90 X AJ91 X AJ92 X X AJ93 X AJ94 X AJ95 X X AJ96 X X Status No Fix No Fix No Fix Plan Fix No Fix Plan Fix No Fix No Fix No Fix No Fix Plan Fix No Fix No Fix No Fix No Fix Plan Fix Plan Fix No Fix Plan Fix Plan Fix No Fix No Fix ERRATA B0-B3 Bits in DR6 May Not be Properly Cleared After Code Breakpoint Performance Monitoring Events for L1 and L2 Miss May Not be Accurate BTM/BTS Branch-From Instruction Address May be Incorrect for Software Interrupts VMLAUNCH/VMRESUME May Not Fail when VMCS is Programmed to Cause VM Exit to Return to a Different Mode Performance Monitor SSE Retired Instructions May Return Incorrect Values REP Store Instructions in a Specific Situation may cause the Processor to Hang A MOV Instruction from CR8 Register with 16 Bit Operand Size Will Leave Bits 63:16 of the Destination Register Unmodified Store to WT Memory Data May be Seen in Wrong Order by Two Subsequent Loads IRET under Certain Conditions May Cause an Unexpected Alignment Check Exception Removed - Not Applicable Non-Temporal Data Store May be Observed in Wrong Program Order Removed - Not Applicable CPUID Reports Architectural Performance Monitoring Version 2 is Supported, When Only Version 1 Capabilities are Available Unaligned Accesses to Paging Structures May Cause the Processor to Hang Microcode Updates Performed During VMX Non-root Operation Could Result in Unexpected Behavior INVLPG Operation for Large (2M/4M) Pages May be Incomplete under Certain Conditions Page Access Bit May be Set Prior to Signaling a Code Segment Limit Fault Update of Attribute Bits on Page Directories without Immediate TLB Shootdown May Cause Unexpected Processor Behavior Invalid Instructions May Lead to Unexpected Behavior EFLAGS, CR0, CR4 and the EXF4 Signal May be Incorrect after Shutdown Performance Monitoring Counter MACRO_INSTS.DECODED May Not Count Some Decoded Instructions The Stack Size May be Incorrect as a Result of VIP/VIF Check on SYSEXIT and SYSRET Performance Monitoring Event SIMD_UOP_TYPE_EXEC.MUL is Counted Incorrectly for PMULUDQ Instruction Storage of PEBS Record Delayed Following Execution of MOV SS or STI Intel® Xeon® Processor 5300 Series 13 Specification Update, December 2010

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

Intel® Xeon® Processor 5300 Series
13
Specification Update, December 2010
AJ73
X
X
No Fix
B0-B3 Bits in DR6 May Not be Properly Cleared After Code
Breakpoint
AJ74
X
X
No Fix
Performance Monitoring Events for L1 and L2 Miss May Not be
Accurate
AJ75
X
X
No Fix
BTM/BTS Branch-From Instruction Address May be Incorrect for
Software Interrupts
AJ76
X
Plan Fix
VMLAUNCH/VMRESUME May Not Fail when VMCS is Programmed
to Cause VM Exit to Return to a Different Mode
AJ77
X
X
No Fix
Performance Monitor SSE Retired Instructions May Return Incorrect
Values
AJ78
X
Plan Fix
REP Store Instructions in a Specific Situation may cause the
Processor to Hang
AJ79
X
X
No Fix
A MOV Instruction from CR8 Register with 16 Bit Operand Size Will
Leave Bits 63:16 of the Destination Register Unmodified
AJ80
X
X
No Fix
Store to WT Memory Data May be Seen in Wrong Order by Two
Subsequent Loads
AJ81
X
X
No Fix
IRET under Certain Conditions May Cause an Unexpected Alignment
Check Exception
AJ82
Removed - Not Applicable
AJ83
X
X
No Fix
Non-Temporal Data Store May be Observed in Wrong Program Order
AJ84
Removed - Not Applicable
AJ85
X
Plan Fix
CPUID Reports Architectural Performance Monitoring Version 2 is
Supported, When Only Version 1 Capabilities are Available
AJ86
X
X
No Fix
Unaligned Accesses to Paging Structures May Cause the Processor
to Hang
AJ87
X
X
No Fix
Microcode Updates Performed During VMX Non-root Operation Could
Result in Unexpected Behavior
AJ88
X
X
No Fix
INVLPG Operation for Large (2M/4M) Pages May be Incomplete
under Certain Conditions
AJ89
X
X
No Fix
Page Access Bit May be Set Prior to Signaling a Code Segment Limit
Fault
AJ90
X
Plan Fix
Update of Attribute Bits on Page Directories without Immediate TLB
Shootdown May Cause Unexpected Processor Behavior
AJ91
X
Plan Fix
Invalid Instructions May Lead to Unexpected Behavior
AJ92
X
X
No Fix
EFLAGS, CR0, CR4 and the EXF4 Signal May be Incorrect after
Shutdown
AJ93
X
Plan Fix
Performance Monitoring Counter MACRO_INSTS.DECODED May
Not Count Some Decoded Instructions
AJ94
X
Plan Fix
The Stack Size May be Incorrect as a Result of VIP/VIF Check on
SYSEXIT and SYSRET
AJ95
X
X
No Fix
Performance Monitoring Event SIMD_UOP_TYPE_EXEC.MUL is
Counted Incorrectly for PMULUDQ Instruction
AJ96
X
X
No Fix
Storage of PEBS Record Delayed Following Execution of MOV SS or
STI
Errata (Sheet 4 of 6)
Number
Steppings
Status
ERRATA
B-3
G-0