Intel MFSYS25 User Guide - Page 134
Storage Redundancy Check Options, IP Configuration,
UPC - 735858196901
View all Intel MFSYS25 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
Storage Redundancy Check Options The purpose of redundancy check is to identify inconsistencies. While the redundancy check does make the data consistent, it does not necessarily correct errors. Redundancy check does provide the user with an indication that drive information may be suspect. The customer can Enable or Disable Redundancy Check schedule by themselves. Figure 76. Storage Redundancy Check schedule IP Configuration The Intel® Management Module has two Gigabit Ethernet connections to each Gigabit Ethernet Switch. These internal connections allow the management module to communicate to the switch module and the external network. The external IP address allows remote browsers to connect to the Intel® Modular Server Control UI and sets the source IP address for email alerts and SNMP traps. The factory default IP address is 192.168.150.150. The default netmask is 255.255.255.0. The IP Configuration screen enables an IT Administrator to change the Intel® Management Module host name and external network access, as well as view the internal configuration. The following is a description of the settings and information found in the IP Configuration tab: • Host Name: Change the management module host name. 118 Intel® Modular Server System User Guide