Intel MFSYS25 User Guide - Page 39

Installing and Removing an Ethernet Switch Module

Page 39 highlights

Installing and Removing an Ethernet Switch Module The Intel® Modular Server System MFSYS25/MFSYS35 ships with one Ethernet switch module pre-installed. Optionally, a second switch module may be installed in the second switch module bay. An ethernet switch module can only be installed in a module bay that is designed to support that device type. The two bays located immediately to the left and right of the Management Module are dedicated to the Ethernet Switch Modules and are labeled ESM. For the exact location of the switch module bay, see Figure 5. The Ethernet switch module may be removed and installed using the steps detailed in the following sections: • "Installing an Ethernet Switch Module" on page 23 • "Removing an Ethernet Switch Module" on page 24 Installing an Ethernet Switch Module To install an ethernet switch module, follow these steps: 1. Review the safety and ESD information at the beginning of this manual and in the appendices. 2. Locate an available switch bay and remove any installed module or filler panel. 3. Release and rotate the module retention lever out and away from the switch module (see letter "A" in Figure 12). 4. Slide the switch module into the selected module bay (see letter "B" in Figure 12) until the bottom of the retention lever engages the bay. Intel® Modular Server System User Guide 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Intel
®
Modular Server System User Guide
23
Installing and Removing an Ethernet Switch Module
The Intel
®
Modular Server System MFSYS25/MFSYS35 ships with one Ethernet switch
module pre-installed. Optionally, a second switch module may be installed in the second
switch module bay. An ethernet switch module can only be installed in a module bay that
is designed to support that device type. The two bays located immediately to the left and
right of the Management Module are dedicated to the Ethernet Switch Modules and are
labeled ESM. For the exact location of the switch module bay, see
Figure 5
.
The Ethernet switch module may be removed and installed using the steps detailed in the
following sections:
“Installing an Ethernet Switch Module” on page 23
“Removing an Ethernet Switch Module” on page 24
Installing an Ethernet Switch Module
To install an ethernet switch module, follow these steps:
1.
Review the safety and ESD information at the beginning of this manual and in the
appendices.
2.
Locate an available switch bay and remove any installed module or filler panel.
3.
Release and rotate the module retention lever out and away from the switch module
(see letter “A” in
Figure 12
).
4.
Slide the switch module into the selected module bay (see letter “B” in
Figure 12
)
until the bottom of the retention lever engages the bay.