Table 8. Error Beep Codes Generated by Intel, Remote Management, Module - cpu
UPC - 735858196055
View all Intel S5000PSL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
In addition to the beep codes above, additional beep codes are provided if an Intel® Remote Management Module is installed. The Intel® Remote Management Module provides the following additional beep codes. Table 8. Error Beep Codes Generated by Intel® Remote Management Module Number of Beeps 1 1-5-1-1 1-5-2-1 1-5-2-3 1-5-2-4 1-5-4-2 1-5-4-3 1-5-4-4 Reason for Beeps and Action to Take Front panel CMOS clear has been initiated. Processor failure. Reseat or replace the failed processor. No processor is installed or the CPU 1 socket is empty. Reseat or replace the failed processor. Processor configuration error or CPU 1 socket is empty. Reseat or replace the failed processor. In a two-processor system, make sure the processors are identical. Front-side bus select configuration error. DC power unexpectedly lost. Chipset control failure. Power control failure. Intel® Server Board S5000PSL 55