Kenmore 7754 Installation Instructions - Page 3

Before, Normal, Installation, Steps

Page 3 highlights

Before Starting Tools You Will Need For leveling legs and Anti=Tip Bracket: • Adjustable wrench or channel lock pliers • 5/16" Nutdriver or Flat Head Screw Driver __ • Electric Drill & 1/8" Diameter Drill Bit (5/32" Masonry Drill Bit if installing in concrete) For gas supply connection: • Pipe wrench l_ For burner flame adjustment: • Phillips head _ and blade-type screwdrivers __:: Additional Materials You Will Need • Gas line shut-offvalve _:_:_. • Pipe joint sealant A new flexible metal appliance conduit (1/2" NPTx 3/4" or 1/2" I.D.) must be design certified byCSA International. Because solid pipe restricts moving the range we recommend using a new flexible conduit (4 to 5 foot length) for each new installation and additional reinstallations. • Always use the (2) new flare union adapters (1/2" NPT x 3/4" or 1/2" I.D.) supplied with the new flexible appliance conduit for connection of the range. Normal Installation Steps 1. Anti-Tip Bracket Installation Instructions Important Safety Warning To reduce the risk of tipping of the appliance, the range must be secured to the floor by properly installed anti-tip bracket and screws packed with the range. Failure to install the anti-tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the appliance itself. If the appliance is ever moved to a different location, the antitip brackets must also be moved and installed with the appliance. Instructions are provided for installation in wood or cement fastened to either the floor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing. A. Locate the Bracket Using the Template - (Bracket may be located on either the left or right side of the appliance. Use the information below to locate the bracket if template is not available). Mark the floor or wall where left or right side of the rangewill be located. If rear of appliance is against thewall or no further than 1-1/4" from wall when installed, you may use the wall orfloor mount method. If molding is installed and does not allow the bracket to fit flush against the wall, remove molding or mount bracket to the floor. For wall mount, locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the appliance. Place bracket on top of template and mark location of the screw holes in wall. If rear of appliance is further than 1-1/4" from thewallwhen installed, attach bracket to the floor. For floor mount, locate the bracket by placing back edge of the template where the rear of the range will be located. Mark the location of the screw holes, shown in template. B= Drill Pilot Holes and Fasten Bracket - Drill a 1/8" pilot hole where screws are to be located. If bracket is to be mounted to the wall, drill pilot hole at an approximate 20 ° downward angle. If bracket is to be mounted to masonry or ceramic floors, drill a 3/16" pilot hole 1-3/4" deep. The screws provided may be used in wood or concrete material. Use a 5/16" nut-driver orflat head screwd river to secure the bracket in place. FASTEN BRACKET (WALOL RFLOOMROUNTING) LevelingLeg -- =-_1 I,_==1=1/4'' Max. _I _F Wall M°unt - J_:: _11 Plate Floor Mount /--Anti-Tip Bracket FASTEN BRACKET (FLOOMROUNTINOGNLY)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Before
Starting
Tools
You Will
Need
For leveling
legs
and
Anti=Tip
Bracket:
Adjustable
wrench or channel lock pliers
5/16" Nutdriver or Flat Head Screw Driver __
Electric Drill & 1/8" Diameter
Drill Bit (5/32" Masonry Drill
Bit if installing
in concrete)
For gas supply
connection:
Pipe wrench
l_
For burner
flame
adjustment:
Phillips
head
_
and
blade-type
screwdrivers
__::
A. Locate
the Bracket
Using
the
Template
- (Bracket
may
be located on
either
the left or right side of the appliance.
Use
the information
below to locate the bracket if template
is not
available).
Mark the floor or wall where left or right side of the
rangewill
be located. If rear of appliance is against thewall or
no further than 1-1/4" from wall when installed, you may use
the wall orfloor
mount method. If molding is installed and does
not allow
the bracket to fit flush
against
the wall,
remove
molding or mount bracket to the floor. For wall mount, locate
the bracket by placing the back edge of the template against
the rear wall and the side edge of template on the mark made
referencing
the side of the appliance.
Place bracket on top of
template and mark location of the screw holes in wall.
If rear
of appliance is further than 1-1/4" from thewallwhen
installed,
attach bracket to the floor. For floor mount, locate the bracket
by placing back edge of the template where
the rear of the
range will be located.
Mark the location of the screw holes,
shown in template.
Additional
Materials
You
Will
Need
Gas line shut-offvalve
_:_:_.
Pipe joint sealant
A new flexible
metal appliance
conduit (1/2" NPTx
3/4"
or 1/2" I.D.) must be design certified byCSA International.
Because
solid
pipe
restricts
moving
the
range
we
recommend
using a new flexible
conduit
(4 to 5 foot
length)
for
each
new
installation
and
additional
reinstallations.
Always use the (2) new flare union adapters
(1/2" NPT x
3/4" or 1/2" I.D.) supplied with the new flexible appliance
conduit for connection
of the range.
Normal
Installation
Steps
1.
Anti-Tip
Bracket
Installation
Instructions
Important
Safety
Warning
To reduce the risk of tipping of the appliance, the range must
be secured to the floor by properly installed anti-tip bracket and
screws
packed with the range. Failure to install the anti-tip
bracket will allow the range to tip over if excessive
weight is
placed on an open door or if a child climbs upon it. Serious
injury might result from spilled hot liquids or from the appliance
itself.
If the appliance is ever moved to a different location, the anti-
tip
brackets
must
also
be moved
and
installed
with
the
appliance.
Instructions
are provided for installation
in wood or cement
fastened to either the floor or wall. When installed to the wall,
make sure that screws completely
penetrate dry wall and are
secured in wood or metal. When fastening to the floor or wall,
be sure that
screws
do not penetrate
electrical
wiring
or
plumbing.
B=
Drill
Pilot
Holes and Fasten
Bracket
- Drill a 1/8" pilot
hole where screws are to be located.
If bracket is to be
mounted to the wall, drill pilot hole at an approximate 20 °
downward
angle. If bracket is to be mounted to masonry
or ceramic floors, drill a 3/16" pilot hole 1-3/4" deep. The
screws provided may be used in wood or concrete material.
Use a 5/16" nut-driver orflat head screwd river to secure the
bracket in place.
FASTEN BRACKET
(WALL
ORFLOOR
MOUNTING)
=-_1
I,_==
1=1/4'' Max.
LevelingLeg
--
_I
_F
Wall M°unt
-
J_::
_11
Plate
Floor
Mount
/--Anti-Tip
Bracket
FASTEN BRACKET (FLOOR
MOUNTING
ONLY)