Kenmore 9787 Installation Instructions - Page 10

Check

Page 10 highlights

Checkfor leaks • Turn on the water faucets and check for leaks. A small amount of water might enter the washer. You will drain this water later. NOTE: Replace inlet hoses after 5 years of use to reduce the risk of hose failure. Record hose installation or replacement dates for future reference. • If you connect only one water hose, you must cap off the remaining water inlet port. • Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found. • The apparatus must be connected to the washer faucets using the new hoses. Do not use old hoses. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the laundry center. Other installations are possible. A I .......D... 1. Move the laundry center to its final location and remove any cardboard used to move the laundry center. 2. Locate the remaining piece of shipping strap. See "Remove Shipping Strap." Shipping strap 3= Wrap the drain hose to the laundry tub leg or standpipe with the shipping strap (A or B below). Push fastener into the nearest hole in the shipping strap. See illustration above. B If the water faucets and the drain standpipe are recessed, put the hooked end of the drain hose in the standpipe. Tightly wrap the shipping strap around the water inlet hoses and the drain hose (C above). Push fastener into the nearest hole in the shipping strap. See illustration above. C ........... _H A. Dryer B. Rigid metal or flexible metal vent C. Clamps D. Wall E. Elbow E Clamps G. Elbow H. Exhaust hood Optional exhaust installations This laundry center can be converted to exhaust out the right or left side. To convert the laundry center, use Side Exhaust Kit Part Number 279823. If your laundry center was previously exhausted from the right or left side, it can be converted to rear exhaust by using standard offset connections. To cover the hole in the side, one of the following plugs can be added: 692790 (white) 3979370 (graphite) 3977784 (biscuit) Follow the instructions in the kit to install. Kits are available from your local Sears store or Sears Service Center. B C A. Standard rear offset exhaust installation B. Rear exhaust for offset close clearance connection C. Left or right side exhaust installation 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Check
for leaks
Turn on the water faucets
and check for leaks. A small
amount
of water might enter the washer. You will drain this
water later.
NOTE:
Replace inlet hoses after 5 years of use to reduce the risk
of hose failure. Record
hose installation
or replacement
dates for
future reference.
If you connect
only one water hose, you must cap off the
remaining
water inlet port.
Periodically
inspect and replace hoses if bulges,
kinks, cuts,
wear, or leaks are found.
The apparatus
must be connected
to the washer faucets
using the new hoses. Do not use old hoses.
1.
Move the laundry center to its final location
and remove any
cardboard
used to move the laundry center.
2.
Locate
the remaining
piece of shipping
strap.
See "Remove
Shipping
Strap."
3=
Shipping
strap
Wrap the drain hose to the laundry tub leg or standpipe
with
the shipping
strap (A or B below).
Push fastener
into the
nearest hole in the shipping
strap.
See illustration
above.
B
If the water faucets
and the drain standpipe
are recessed,
put
the hooked
end of the drain hose in the standpipe.
Tightly
wrap the shipping
strap around
the water inlet hoses and the
drain hose (C above). Push fastener
into the nearest
hole in
the shipping
strap.
See illustration
above.
Choose
your exhaust
installation
type
Recommended
exhaust
installations
Typical installations
vent the dryer from the rear of the laundry
center. Other installations
are possible.
A
I
..........
D
C
...........
_H
A. Dryer
E. Elbow
B. Rigid metal or flexible metal
vent
E
Clamps
C. Clamps
G. Elbow
D. Wall
H. Exhaust hood
Optional
exhaust
installations
This laundry center can be converted
to exhaust
out the right or
left side. To convert the laundry center, use Side Exhaust
Kit Part
Number 279823.
If your laundry center was previously
exhausted
from the right or left side, it can be converted
to rear exhaust
by
using standard
offset connections.
To cover the hole in the side,
one of the following
plugs
can be added:
692790 (white)
3979370
(graphite)
3977784
(biscuit)
Follow the instructions
in the kit to install. Kits are available from
your local Sears store or Sears Service
Center.
B
C
A. Standard
rear offset
exhaust
installation
B. Rear
exhaust
for offset close clearance
connection
C. Left or right
side exhaust
installation
10