Kenwood KDC-X889 Instruction Manual - Page 44
Built-in Amp Setting, G-Counter Level set, G-Analyzer Reset, G-Analyzer Calibration setup, G-
View all Kenwood KDC-X889 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Menu system In Standby mode Built-in Amp Setting Built-in amplifier is controlled. Turning OFF this control enhances the preout quality. Display "AMP : ON" "AMP : OFF" Setting The built-in amplifier activates. The built-in amplifier deactivates. Function of the KDC-X889/KDC-MP828/KDCMP7028/KDC-MP728/KDC-X789 In Standby mode G-Counter Level set Calibrating G-Counter. Setting the level according to the kinds of vehicles. Display "G-Counter: Level1" "G-Counter: Level2" "G-Counter: Level3" ... Setting Counter is easy to go up. Counter is hard to go up. • In the case of less acceleration, set it up to "G-Counter: Level1". In the case of frequent acceleration, set it up to "G-Counter: Level3". Function of the KDC-X889/KDC-MP828/KDCMP7028/KDC-MP728/KDC-X789 In Standby mode G-Analyzer Calibration setup G-Analyzer requires calibration for horizontal acceleration and braking. • Detection of horizontal and straight directions should be done at horizontal location to go straight. 1 Park the vehicle at horizontal location 2 Select G-Analyzer Calibration set mode Push the Control knob to [FM] or [AM]. Select the "G-Calibration" display. 3 Enter G-Analyzer Calibration set mode Press the Control knob for at least 1 second. "Stop" is displayed. 4 Start Calibration of horizontal direction Press the Control knob. Once "Move Forward" appears on the display, the vehicle must be advanced. 5 Start Calibration of straight direction When the vehicle is driven on the straight direction, calibration of straight direction automatically starts. Function of the KDC-X889/KDC-MP828/KDCMP7028/KDC-MP728/KDC-X789 In Standby mode G-Analyzer Reset Resets the value of G-Meter and G-Counter. 1 Select G-Analyzer Reset mode Push the Control knob to [FM] or [AM]. Select the "G-Reset" display. 2 Enter G-Analyzer Reset mode Press the Control knob for at least 1 second. 3 Select the Reset item Push the Control knob to [FM] or [AM]. "G-Meter Reset": Reset the value of G-Meter. "G-Counter Reset": Reset the value of G-Counter. 4 Reset the value Press the Control knob for at least 2 seconds. "Reset OK" is displayed. 5 Exit G-Analyzer Reset mode Press the [MENU] button. 44 | English • In order to operate the detection of straight direction. When the Calibration is finished, "Calibration OK" is displayed. • If you fail to complete the calibraton, "No Calibration" is displayed. In such a case, repeats step 1 thru 6. 6 Exit G-Analyzer Calibration set mode Press the [MENU] button. Function of the KDC-X889/KDC-MP828/KDCMP7028/KDC-MP728/KDC-X789 G-Analyzer Stop Watch The control of stop watch can be started by GAnalyzer function.