LG LFX28968SW Service Manual - Page 30

Icing Fan Error Er IF

Page 30 highlights

8-7 Icing Fan Error (Er IF) No Checking flow 1 Reset the unit and Input Test 1 Mode. (Push the button 1 time) 2 Open the refrigerator door and Check the air flow. ※ While an error code is displayed, the fan is not working. 3 Check the Connector. (Frozen caused the PCB short) Result & SVC Action Status SVC Action No windy Go to the 3,4 Windy Go to the 5 4 Check the Fan motor. (Frozen, Lock, ect.) 5 Check the Fan motor voltage. Point Result SVC Action (1)Pin1, (2)Pin3, (3)Pin5 (2) ~ (3) Below 7 V Change the PCB (1) ~ (3) 0 or 5 V Change the motor - 30 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

- 30 -
8-7
Icing Fan Error (Er IF)
No
1
2
Checking flow
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
Open the refrigerator door and Check the
air flow.
While an error code is displayed,
the fan is not working.
3
Check the Connector.
(Frozen caused the PCB short)
Result & SVC Action
Status
No windy
Windy
SVC Action
Go to the 3,4
Go to the 5
4
Check the Fan motor.
(Frozen, Lock, ect.)
5
Check the Fan motor voltage.
Below 7 V
0 or 5 V
(2) ~ (3)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
<CON7>
(1)Pin1, (2)Pin3, (3)Pin5