LG LFX28968SW Service Manual - Page 47
Sheath Heater, Function, How to, Measure, Standard, Sheath heater at all temperature
View all LG LFX28968SW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
11-2 Sheath Heater Function Sheath heater is a part for defrost. All heating wire is connected to only one line. To check if the part is defective, check the resistance. How to Measure Set a ohmmeter connect to The 2 housing pin. Measure the 2 pin connected to Sheath Heater. If the ohmmeter indicate (V°øV)/Watt=R is good condition, ex) when watt=350w, voltage=115v R=(115°ø115)/350=38Ω But if the ohm meter indicate infinity the Sheath heater is bad. (1) (2) Standard Sheath heater (at all temperature) Test Point (1) to (2) Ressult 34 ~ 42Ω - 47 -
- 47 -
11-2 Sheath Heater
Function
Sheath heater is a part for defrost. All heating wire is connected to only one line. To check if
the part is defective, check the resistance.
How to
Measure
Set a ohmmeter connect to The 2 housing pin.
Measure the 2 pin connected to Sheath Heater.
If the ohmmeter indicate (V°øV)/Watt=R is good condition,
ex) when watt=350w, voltage=115v R=(115°ø115)/350=38
Ω
But if the ohm meter indicate infinity the Sheath heater is bad.
Standard
Sheath heater (at all temperature)
Test Point
(1) to (2)
Ressult
34 ~ 42
Ω
(1)
(2)