LG LFX28968SW Service Manual - Page 51

AC Motor ASSEMBLY, Function, How to, Measure, < In-door Motor &gt, Standard, Geared Motor

Page 51 highlights

11-6 AC Motor ASSEMBLY Function The motor in the door pushed the ice into the dispenser. How to Measure < In-door Motor > 1 Separate the housing. < In-door Motor > 1 Separate the housing. 2 Measure the resistance between (1) and (2) 2 Measure the resistance between (1) and (3) (1) (2) (1) (3) Check the resistance between connectors (In-door motor 1, 2) and (In-door motor 1, 3). It means check whether or not applying an Electric current. If there is resistance, it means the geared motor or solenoid is not inferiority Standard Geared Motor Test Points (1) to (2) (1) to (3) Result 31.1 ~ 42.09Ω 31.1 ~ 42.09Ω - 51 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

- 51 -
11-6 AC Motor ASSEMBLY
Function
The motor in the door pushed the ice into the dispenser.
How to
Measure
< In-door Motor >
< In-door Motor >
Standard
Geared Motor
Test Points
(1) to (2)
(1) to (3)
Result
31.1 ~ 42.09
31.1 ~ 42.09
Separate the
housing.
Measure the
resistance between
(1) and (2)
Check the resistance between connectors (In-door motor 1, 2) and
(In-door motor 1, 3). It means check whether or not applying an
Electric current. If there is resistance, it means the geared motor or
solenoid is not inferiority
(1)
(2)
(3)
(1)
1
2
Separate the
housing.
Measure the
resistance between
(1) and (3)
1
2