LG LFX28968SW Service Manual - Page 41

Check the R Sensor resistance.

Page 41 highlights

9-8 Over cooling in Refrigerator room No Checking flow 1 Check the R Sensor resistance. ※ The R Sensor is determined by the temperature. For example, 30㏀ indicates 32°F. 2 Reset the unit and Input Test 1 Mode. (Push the button 1 time) Result & SVC Action Temperature 23°F / -5°C 32°F / 0°C 41°F / 5°C 50°F / 10°C 59°F / 15°C Result 38 ㏀ 30 ㏀ 24 ㏀ 19.5 ㏀ 16 ㏀ 3 Open Refrigerator room door and Check the air flow. 4 Input Test 2 Mode and Check the air flow. (push the button 1 more time) Status Windy No windy SVC Action Go to the 4 Check the R Fan Check the damper (Go to the 5) Status Windy No windy SVC Action Go to the 5 It's normal 5 Check the damper resistance. (1) (2) (3) (4) Test Point (1) To (2) (3) To (4) Result 370 ~ 450 Ω Other 370 ~ 450 Ω Other SVC Action It's normal Change damper It's normal Change damper - 41 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

- 41 -
9-8
Over cooling in Refrigerator room
No
1
Checking flow
Check the R Sensor resistance.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open Refrigerator room door and Check
the air flow.
The R Sensor is determined by
the temperature.
For example, 30
indicates 32°F.
Result & SVC Action
Status
Windy
No windy
SVC Action
Go to the 4
Check the R Fan Check
the damper (Go to the 5)
4
Input Test 2 Mode and
Check the air flow.
(push the button 1 more time)
Status
Windy
No windy
SVC Action
Go to the 5
It’s normal
5
Check the damper resistance.
<CON7>
Temperature
23°F
/ -5
°C
32°F
/ 0
°C
41°F
/ 5
°C
50°F
/ 10
°C
59°F
/ 15
°C
Result
38
30
24
19.5
16
(1) To (2)
(3) To (4)
370 ~ 450
Other
370 ~ 450
Other
It’s normal
Change damper
It’s normal
Change damper
Result
SVC Action
Test
Point
(1)
(2)
(3)
(4)