LG LFX28968SW Service Manual - Page 55
Compressor Troubleshooting
View all LG LFX28968SW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
12. Compressor Troubleshooting PCB Check (Simplify) A-inverter Power Off Con201 Disconnect TEST 1 Mode Protection Logic Power On Time>30sec & V≒200 Y PCB OK N Replace Driver PCB Test Button Check Voltage about 200V past 30second after turn on Test Mode Ref. TEST1 Forced Starting Comp FLA075(A-Inverter) TDC (Full Stroke) Display & sound Display ON, Buzz 1 time Troubleshooting Refer Not Cooling Recheck Reset LED Y Blink? N LED blink 1 LED blink 7 LED blink 5 LED blink2 LED blink record LED blink record LED blink record LED blink record Check C LED blink6 LED blink record Reset Reset LED blink 1 LED blink 7 Comp. Y Check? N Replace Driver PCB Replace Driver PCB Reset LED blink 5 Comp. N Work? Comp. N Check? Replace Comp. Heavy Repair Y Y Leakage? N Recheck Reset LED blink2 Comp. N Work? Harness Y Check? Y N Fix Harness Heavy Repair Y Refrigerant N leak? Recheck Comp. N Check? Reset LED blink6 Comp. N Work? Y Y N Heavy Repair Leakage? Comp. N Check? Recheck Heavy Repair Comp. N Work? Y Y Refrigerant N leak ? IPM output > 80V-20% Y Recheck N Replace Driver PCB Comp. N Check? - 55 -