LG LFX28968SW Service Manual - Page 39

Closed, working, Damper is normal., Go to 6, Change the damper, Other, It's normal, Change damper,

Page 39 highlights

No Checking flow 5 Damper checking method. Inputting TEST Mode, Check the damper and PCB. (1) (2) (3) (4) 6 Check the Fan motor. Rotate fan using your hand. Stuck change the motor. (Cause of ice or rust inside of motor) Result & SVC Action Test Damper Mode State 1 Mode Open 2 Mode Closed 1,2 Not mode working SVC Action Damper is normal. (Go to 6) Change the damper Point (1) to (2) (3) to (4) Result 370 ~450Ω Other 370 ~450Ω Other SVC Action It's normal Change damper It's normal Change damper Point Motor Result Sticky Not Sticky SVC Action Change the motor Change the PCB - 39 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

- 39 -
No
5
Checking flow
Damper checking method.
Inputting TEST Mode,
Check the damper and PCB.
6
Check the Fan motor.
Rotate fan using your hand.
Stuck change the motor.
(Cause of ice or rust inside of motor)
Result & SVC Action
(1)
(3)
(2)
(4)
Open
Closed
Not
working
1 Mode
2 Mode
1,2
mode
Damper is normal.
(Go to 6)
Change the damper
Test
Mode
Damper
State
SVC Action
(1) to (2)
(3) to (4)
370 ~450
Other
370 ~450
Other
It’s normal
Change damper
It’s normal
Change damper
Point
Result
SVC Action
Sticky
Not Sticky
Motor
Change the motor
Change the PCB
Point
Result
SVC Action