Lexmark X864 Forms and Bar Code Technical Reference - Page 27

Each of the V parameter values For Forms and Bar Code Card: 33

Page 27 highlights

Field Name Type Esc(s#1,#2,#3,#4S int Esc(s#P int Range Default (if not specified) Min: Min. value is 1, but symbol will be too small to be readable. Max: There is no max value but larger values will produce a symbol that will not fit on the page. 8,16,24,32 (dec) or 8,10,18,20 (hex) 0=Default 1=No HRT 2=Embedded 3=Half-Embedded 4=Under 0 (dec) or 00 (dec) Description Optional. Selects the width of the spaces. Optional. Defines the HRT Location. Note: HRT is not available on RSS-14 Stacked. Notes: • The default V parameter observed for the HP BarDIMM Pro ver 3.3A is: - Standard: 32 (11mm) - Truncated: 12 (4mm) - Stacked: 13 (4mm total height) - Limited: 10 (3mm) • Some of the Forms and Bar Code Card default V parameter values (in the above table) are slightly different than HP, and match the RSS-14 AIM specification values. • Each of the V parameter values (For Forms and Bar Code Card: 33, 13, 13, 10, and 34 respectively in the table above) is considered in the RSS-14 AIM specification as a multiple of "X", which is a "module width", assumed to be 1 by bar code engine. • Only the value for Bar Width 1 is needed for the design of the 2D addon. All other bar widths are dependent on the value of Bar Width 1. • The S parameter does not work correctly on the HP BarDIMM and also with the Forms and Bar Code Card. Setting S1 to any value does not affect the bar code like it does with B1. The S parameter should vary the whitespace widths on the Forms and Bar Code Card like it does on other one-dimensional bar codes. One-dimensional bar codes 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165

One-dimensional bar codes
24
Notes:
The default V parameter observed for the HP BarDIMM Pro ver 3.3A is:
Standard: 32 (11mm)
Truncated: 12 (4mm)
Stacked: 13 (4mm total height)
Limited: 10 (3mm)
Some of the Forms and Bar Code Card default V parameter values (in the above table) are
slightly different than HP, and match the RSS-14 AIM specification values.
Each of the V parameter values (For Forms and Bar Code Card: 33, 13, 13, 10, and 34
respectively in the table above) is considered in the RSS-14 AIM specification as a multiple of
“X”, which is a “module width”, assumed to be 1 by bar code engine.
Only the value for Bar Width 1 is needed for the design of the 2D addon. All other bar widths
are dependent on the value of Bar Width 1.
The S parameter does not work correctly on the HP BarDIMM and also with the Forms and
Bar Code Card. Setting S1 to any value does not affect the bar code like it does with B1. The
S parameter should vary the whitespace widths on the Forms and Bar Code Card like it does
on other one-dimensional bar codes.
Esc(s#1,#2,#3,#4S
int
Min:
Min. value is 1, but
symbol will be too small
to be readable.
Max:
There is no max value
but larger values will
produce a symbol that
will not fit on the page.
8,16,24,32 (dec)
or
8,10,18,20 (hex)
Optional.
Selects the width of the
spaces.
Esc(s#P
int
0=Default
1=No HRT
2=Embedded
3=Half-Embedded
4=Under
0 (dec)
or
00 (dec)
Optional.
Defines the HRT
Location.
Note:
HRT is not
available on RSS-14
Stacked.
Field Name
Type
Range
Default
(if not specified)
Description