For more information on the specifications implemented on the PLANET code, refer
View all Lexmark X864 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Key /EmbedText Type name /FontName name /QuietZone [int int] PLANET Codes Key /Symbology Type name /Pitch int /QuietZone [int int] Range Default value Description /NoText /Under /Above /NoText Optional. Defines if and where the HRT is to be printed. See these sections: • Values for / EmbedText key • Values for / FontName key /Courier-Bold Optional. Defines how the HRT is to be printed. When the value given is not within the defined range: • If the value is of type name, the value will be set to default (/Courier-Bold) • If the value is of any other type, a TYPECHECK error will be returned. Min: [0 0] (dec) Max: [1200 1200] (dec) • [150 150] (dec) or • [96 96] (hex) Optional. Note: Values less than the minimum will use the default value of [150 150]. Range n/a 20-24 (dec) Minimum: [0 0] (dec) Maximum: [1200 1200] (dec) Default value Description n/a Required. /PLANET • 22 (dec) or • 16 (hex) Optional. Selects the bar pitch of the PLANET bar code. Values less than 20 (dec) or 14 (hex) result in a pitch of 20. Values greater than 24 (dec) or 18 (hex) result in a pitch of 24. • [150 150] (dec) or • [96 96] (hex) Optional. Note: Values less than the minimum will use the default value of [150 150]. Note: For more information on the specifications implemented on the PLANET code, refer to Appendix B and C of the USPS PLANET Specifications. Two-dimensional bar codes 84