Units Enumeration for X Dimension: Default = 02x, ECC by Predetermined Value: Default = 00x

Page 53 highlights

ECC by Predetermined Value: (Default = 00x) This byte designates error correction levels by predetermined values. Valid predetermined values are 0-8. If the value of this byte is anything other than 0-8, the ECC level is set to 0. Predetermined values 00x 01x 02x 03x 04x 05x 06x 07x 08x Number of error code words 2 4 8 16 32 64 128 256 512 ECC can also be specified as a percentage. A valid non-zero ECC by Percentage will override ECC by Predetermined Value. See "ECC by percentage, bytes 1 and 2: (Default = 0000x)" on page 51. Units Enumeration for X Dimension: (Default = 02x) This byte sets the units used in specifying the X Dimension (the smallest element width). Supported values are 01x for 300 dpi units, 02x for 600 dpi units, and 03x for 1200 dpi units. X Dimension, bytes 1 and 2: (Default = 0005x) These two bytes set the X Dimension. To set the narrowest element to 5/300 of an inch, the Units Enumeration should be set to 01x, and these two bytes would be 00x and 05x. Y Ratio: (Default = 03x) This sets the bar height in terms of narrowest element width. If the X Dimension is 5/300 inch, then to set the bar height to 15/300 inch, this byte would be 03x. Truncated: (Default = 00x) This byte determines whether to omit the right row indicator and stop pattern. A value of 01x activates truncation. All other values disable truncation. Rows: (Default = 00x) This can be used to manually set the number of symbol rows. Both rows and columns must be 00x if using aspect ratio. Valid non-zero values are 03x to 5Ax (3 to 90 decimal). A value of 3 will be used in place of any specified non-zero value less than 3, and a value of 90 will be used in place of any specified non-zero value greater than 90. If columns is a valid non-zero value, and rows is 0, the Two-dimensional bar codes 50

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165

Two-dimensional bar codes
50
ECC by Predetermined Value: (Default = 00x)
This byte designates error correction levels by predetermined values. Valid predetermined values are
0-8. If the value of this byte is anything other than 0-8, the ECC level is set to 0.
ECC can also be specified as a percentage.
A valid non-zero ECC by Percentage will override ECC
by Predetermined Value. See “ECC by percentage, bytes 1 and 2: (Default = 0000x)” on page 51.
Units Enumeration for X Dimension: (Default = 02x)
This byte sets the units used in specifying the X Dimension (the smallest element width). Supported
values are 01x for 300 dpi units, 02x for 600 dpi units, and 03x for 1200 dpi units.
X Dimension, bytes 1 and 2: (Default = 0005x)
These two bytes set the X Dimension. To set the narrowest element to 5/300 of an inch, the Units
Enumeration should be set to 01x, and these two bytes would be 00x and 05x.
Y Ratio: (Default = 03x)
This sets the bar height in terms of narrowest element width. If the X Dimension is 5/300 inch, then to
set the bar height to 15/300 inch, this byte would be 03x.
Truncated: (Default = 00x)
This byte determines whether to omit the right row indicator and stop pattern. A value of 01x
activates truncation. All other values disable truncation.
Rows: (Default = 00x)
This can be used to manually set the number of symbol rows.
Both rows and columns must be 00x if
using aspect ratio. Valid non-zero values are 03x to 5Ax (3 to 90 decimal).
A value of 3 will be used
in place of any specified non-zero value less than 3, and a value of 90 will be used in place of any
specified non-zero value greater than 90.
If columns is a valid non-zero value, and rows is 0, the
Predetermined values
Number of error code words
00x
2
01x
4
02x
8
03x
16
04x
32
05x
64
06x
128
07x
256
08x
512