Lexmark X864 Forms and Bar Code Technical Reference - Page 88
Arguments for PDF417 bar code symbology, Default, Value, Definition
View all Lexmark X864 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Arguments for PDF417 bar code symbology Key /Symbology /Type Type Name integer /Rows integer /Columns integer /AspectRatio real /Units /ModuleWidth integer /Height integer Default Value Definition Required (/PDF417); signifies the bar code symbology Required; 0 for /Rows and /Columns set manually or 1 for /Rows and /Columns determined by /AspectRatio Required if /Type = 0; manually sets number of symbol rows; valid values are 3 to 90; any values outside this range will cause a RANGECHECK error Required if /Type = 0; manually sets number of symbol columns; valid values are 1 to 30; any values outside this range will cause a RANGECHECK error Required if /Type = 1; alternate way of designing rows and columns the ratio is height/width; valid values are 0.1 to 10.0; any values outside this range will cause a value of 0.5 to be used Example: For a height-to-width ratio of 2/3, set /AspectRatio equal to 0.67. Optional; 1/600 inch Required; in /Units, specifies the X dimension (smallest element width) Example: A value of 15 specifies an element width of 15/600 inch. Required; specifies the bar height in terms of /ModuleWidth Example: When /ModuleWidth is set to 15, a value of 3 sets the bar height to 45/600 inch. Arguments for PDF417 bar code symbology 85