Key /QuietZone /Units Range [int int] Default value [150 150] [array of integers] Description Same as the other bar codes, in /Units (optional) 1/600 inch (optional) /BarHeight must be: • greater than or equal to 20 mm for module widths less than or equal to 0.45 mm (0.0177 inches) • greater than or equal to 23 mm for module widths greater than 0.45 mm (0.0177 inches) Post 4-State bar code descriptors 80
Post 4-State bar code descriptors
80
/BarHeight
must be:
•
greater than or equal to 20 mm for module widths less than or equal to 0.45 mm (0.0177
inches)
•
greater than or equal to 23 mm for module widths greater than 0.45 mm (0.0177 inches)
/QuietZone
[int int]
[150 150]
[array of
integers]
Same as the other bar codes, in /Units
(optional)
/Units
1/600 inch (optional)
Key
Range
Default value
Description