LiftMaster CSW24VDC CSW24VDC Installation Manual - Page 19

STEP 9 continued..., 33AH BATTERIES

Page 19 highlights

STEP 9 continued... CONNECT BATTERIES INSTALLATION 33AH BATTERIES The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. The 33AH application requires the 33AH wire harness (Model K94-37236) and an additional battery tray (Model K10-36183) to allow more space in the enclosure. The heater option cannot be used with the 33AH battery application. 1. Locate the J15 plug on the control board and disconnect it. 2. Connect the white jumper from the 33AH wire harness kit between the positive (+) terminal of one battery and the negative (-) terminal of the other battery. 3. Connect one end of the red (+) wire from the 33AH wire harness kit to the red wire from the J15 plug as shown. Connect the other end of the red (+) wire to the positive (+) terminal on the battery as shown. 4. Connect one end of the black (-) wire from the 33AH wire harness kit to the black wire from the J15 plug as shown. Connect the other end of the black (-) wire to the negative (-) terminal on the battery as shown. 5. Turn ON AC power to the operator. 6. Turn ON the AC power switch on the operator. 7. Reconnect the J15 plug to the control board. NOTE: You may see a small spark when plugging the J15 plug into the board. J15 Plug Red (+) Black (-) Red (+) wire from new wire harness kit White jumper from new wire harness kit Black (+) wire from new wire harness kit + -+ - 33AH Batteries 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

18
Red (+)
wire from
new wire
harness kit
Red (+)
Black (-)
Black (+) wire
from new wire
harness kit
33AH Batteries
+
+
White jumper from
new wire harness kit
J15 Plug
INSTALLATION
STEP 9 continued...
CONNECT BATTERIES
33AH BATTERIES
The batteries are charged in the circuit by the integrated transformer. The
batteries are for battery backup or solar installation. The 33AH application
requires the 33AH wire harness (Model K94-37236) and an additional
battery tray (Model K10-36183) to allow more space in the enclosure.
The heater option cannot be used with the 33AH battery application.
1.
Locate the J15 plug on the control board and disconnect it.
2.
Connect the white jumper from the 33AH wire harness kit between the
positive (+) terminal of one battery and the negative (-) terminal of the
other battery.
3.
Connect one end of the red (+) wire from the 33AH wire harness kit to
the red wire from the J15 plug as shown. Connect the other end of
the red (+) wire to the positive (+) terminal on the battery as shown.
4.
Connect one end of the black (-) wire from the 33AH wire harness kit
to the black wire from the J15 plug as shown. Connect the other end
of the black (-) wire to the negative (-) terminal on the battery as
shown.
5. Turn ON AC power to the operator.
6. Turn ON the AC power switch on the operator.
7.
Reconnect the J15 plug to the control board.
NOTE:
You may see a
small spark when plugging the J15 plug into the board.