LiftMaster CSW24VDC CSW24VDC Installation Manual - Page 22

Step 11 Install The Cover, Install The Cover

Page 22 highlights

INSTALLATION STEP 11 INSTALL THE COVER The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up. The front cover and access door can be locked with the key. 1. Remove the operator arm from the output shaft by releasing the handle. 2. Align the tabs on the rear cover with the slots on the chassis and place the cover over the operator. 3. Secure both sides of the rear cover to the chassis with two 5/16-18 lead in screws. 4. Reattach the operator arm to the output shaft (making sure the pin fits into the slot) and secure by pushing the handle down. 5. Place the operator arm cover over the operator arm and secure. 6. Align the front cover with the back cover, making sure the grooves line up. 7. Secure the front cover to the chassis with two 5/16-18 lead in screws. 8. Secure the front cover to the rear cover using the 5/16-18 lead in screw. 5/16-18 Lead In Screws Tabs on Rear Cover 5/16-18 Lead In Screw Slots on Chassis Groove on Front Cover TO LOCK THE ACCESS DOOR From the factory the access door for the reset switch will not be locked. To lock the access door follow the steps below: 1. Locate the lock tab on the back of the front cover and remove the screw securing the tab to the cover. 2. Turn the tab 180 degrees, then secure with the screw. The access door can now be locked. Access Door Lock Tab Access Door The basic installation is complete. Factory Default position 21 (back of front cover)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

21
1.
Remove the operator arm from the output shaft by releasing the
handle.
2.
Align the tabs on the rear cover with the slots on the chassis and
place the cover over the operator.
3.
Secure both sides of the rear cover to the chassis with two 5/16-18
lead in screws.
4.
Reattach the operator arm to the output shaft (making sure the pin fits
into the slot) and secure by pushing the handle down.
5. Place the operator arm cover over the operator arm and secure.
6.
Align the front cover with the back cover, making sure the grooves
line up.
7.
Secure the front cover to the chassis with two 5/16-18 lead in screws.
8.
Secure the front cover to the rear cover using the 5/16-18 lead in
screw.
The basic installation is complete.
STEP 11
INSTALL THE COVER
The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access
the reset switch slide the access door up. The front cover and access door can be locked with the key.
TO LOCK THE ACCESS DOOR
From the factory the access door for the reset switch will not be locked.
To lock the access door follow the steps below:
1.
Locate the lock tab on the back of the front cover and remove the
screw securing the tab to the cover.
2.
Turn the tab 180 degrees, then secure with the screw. The access
door can now be locked.
Tabs on Rear Cover
Slots on Chassis
Groove on Front Cover
5/16-18
Lead In
Screws
5/16-18
Lead In
Screw
Access Door
Lock Tab
Factory Default position
(back of front cover)
Access Door
INSTALLATION