Maytag MGDE300VF Installation Instructions - Page 8

Electric, Dryer Power Hookup, Canada

Page 8 highlights

ELECTRIC DRYER POWER HOOKUP- CANADA ONLY Electrical Requirements Electrical Shock Hazard Plug into a grounded 4 prong outlet. Failure to do so can result in death or electrical shock. It is your responsibility • Tocontact a qualifiedelectrical installer. To be sure that the electrical connection is adequate and in conformance with the Canadian Electrical Code, C22.1-1atest edition and all local codes. A copy of the above codes standard may be obtained from: Canadian Standards Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA. To supply the required 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14-30R wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within reach of dryer's final location. For further information, please reference the service numbers located in the "Assistance or Service" section. GROUNDING INSTRUCTIONS [] For a grounded, cord-connected dryer: This dryer must be grounded, in the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipmentgrounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING: improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician. SAVE THESE INSTRUCTIONS 4-wire receptacle 14-30R If using a replacement power supply cord, it is recommended that you use Power Supply Cord Replacement Part Number 9831317. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

ELECTRIC
DRYER POWER HOOKUP-
CANADA
ONLY
Electrical Requirements
Electrical
Shock
Hazard
Plug into
a
grounded
4 prong
outlet.
Failure
to do so can
result
in
death
or
electrical
shock.
It is your responsibility
Tocontact a qualifiedelectrical
installer.
To be sure that the electrical connection
is adequate and in
conformance
with the Canadian Electrical Code, C22.1-1atest
edition and all local codes. A copy of the above codes standard
may be obtained from: Canadian Standards Association,
178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit,
fused on both sides of the line. A time-delay
fuse or circuit
breaker is recommended.
Connect to an individual branch
circuit.
This dryer is equipped with a CSA International
Certified Power
Cord intended to be plugged into a standard
14-30R wall
receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall
receptacle
is within reach of dryer's final location.
4-wire receptacle
14-30R
For further information,
please reference the service numbers
located in the "Assistance
or Service" section.
GROUNDING
INSTRUCTIONS
[] For a grounded,
cord-connected
dryer:
This dryer must be grounded,
in the event of malfunction
or
breakdown,
grounding
will reduce the risk of electric shock
by providing
a path of least resistance
for electric current.
This dryer
is equipped
with a cord having an equipment-
grounding
conductor
and a grounding
plug. The plug must
be plugged
into an appropriate
outlet that is properly
installed
and grounded
in accordance
with all local codes
and ordinances.
WARNING:
improper
connection
of the equipment-
grounding
conductor
can result in a risk of electric
shock.
Check with
a qualified
electrician
or service
representative
or personnel
if you are in doubt
as to whether
the dryer
is
properly
grounded.
Do not modify the plug provided
with
the dryer: if it will not fit the outlet,
have a proper
outlet
installed
by a qualified
electrician.
SAVE
THESE
INSTRUCTIONS
If using a replacement
power supply cord, it is recommended
that
you use Power Supply Cord Replacement
Part Number 9831317.
8