McAfee IIP-M80K-ISAA Product Guide - Page 25

Attaching Cables to the M-8000, Cabling the Console port, Cabling the Auxiliary port

Page 25 highlights

CHAPTER 4 Attaching Cables to the M-8000 Follow the steps outlined in this chapter to connect cables to the various ports on your sensor. Cabling the Console port The Console port on M-8000 P is used for setup and configuration of the sensor. You can use the Console port on M-8000 S to recover the flash image. 1 For console connections, plug the DB9 Console cable supplied by McAfee into the Console port (labeled Console on the sensor front panel) on M-8000 P. 2 Connect the other end of the Console port cable directly to a COM port of the PC or terminal server you will use to configure the sensor (for example, a PC running correctly configured Windows HyperTerminal software). You must connect directly to the console for initial configuration. Required settings for HyperTerminal are: Name Setting Baud rate Number of bits Parity Stop bits Flow Control 3 Power on the sensor. 38400 8 None 1 None Cabling the Auxiliary port The Auxiliary (Aux) port is also used for modem access to the sensor for setup and configuration. You cannot use a modem the first time you configure a sensor. 1 For modem connections, plug a straight-through modem cable into the Auxiliary port (labeled Aux on the sensor front panel) on M-8000 P. 2 Connect a modem to the Aux port. Connect a telephone line to the modem. Required settings for the Aux port are: 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

C
HAPTER
4
Attaching Cables to the M-8000
Follow the steps outlined in this chapter to connect cables to the various ports on
your sensor.
Cabling the Console port
The Console port on M-8000 P is used for setup and configuration of the sensor. You
can use the Console port on M-8000 S to recover the flash image.
1
For console connections, plug the DB9 Console cable supplied by McAfee into
the
Console
port (labeled
Console
on the sensor front panel) on M-8000 P.
2
Connect the other end of the Console port cable directly to a COM port of the PC
or terminal server you will use to configure the sensor (for example, a PC running
correctly configured Windows HyperTerminal software). You must connect
directly to the console for initial configuration.
Required settings for HyperTerminal are:
Name
Setting
Baud rate
38400
Number of bits
8
Parity
None
Stop bits
1
Flow Control
None
3
Power on the sensor.
Cabling the Auxiliary port
The Auxiliary (
Aux
) port is also used for modem access to the sensor for setup and
configuration.
You cannot use a modem the first time you configure a sensor.
1
For modem connections, plug a straight-through modem cable into the Auxiliary
port (labeled
Aux
on the sensor front panel) on M-8000 P.
2
Connect a modem to the
Aux
port.
Connect a telephone line to the modem.
Required settings for the
Aux
port are:
17