Panasonic AW-HN38H AW-HN38H Operating Instructions - Page 91

Common to IPv6/IPv4, Primary DNS server address

Page 91 highlights

Web screen configurations (continued) DNS Whether the DNS server address is to be acquired automatically (Auto) or manually (Manual) is input here. If "Manual" has been selected, the DNS settings must be established. If "Auto" is selected when the DHCP function is going to be used, the DNS server address is acquired automatically. For further details, consult your system administrator. Setting value: Auto, Manual Factory settings: Auto Primary server address Secondary server address Input the IP address of the DNS server if the "Manual" setting has been selected for "DNS". For details on the IP address of the DNS server, consult your system administrator. zzIPv6 network Manual Enable or disable manual configuration of the IPv6 address. Factory settings: Off IP address(IPv6) When [Manual] is set to [On], the IPv6 address must be entered manually. Be sure to enter an address unique from other devices. Note ●● When connecting to the manually specified IP address through a router, use an IPv6-compatible router, and enable the automatic configuration function for the IPv6 address. Be sure to configure an IPv6 address that includes the prefix information provided by the IPv6-compatible router. For details, refer to the operating instructions for the router. Default gateway When [Manual] is set to [On] for [IPv6 network], enter the default gateway for the unit's IPv6 network. Factory settings: blank DHCPv6 Enable or disable use of the IPv6 DHCP function. Configure the DHCP server so that the same IP address is not configured for a personal computer that does not use the DHCP function and other network cameras. For details on server settings, consult your network administrator. Factory settings: Off Primary DNS server address Secondary DNS server address Enter the IPv6 address of the DNS server. For details on the IPv6 address of the DNS server, consult your system administrator. zzCommon (to IPv6/IPv4) HTTP port Port numbers are allocated separately. Setting range: 1 to 65535 The following port numbers are used by the unit so they cannot be used. 20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000 to 61000 Factory settings: 80 Max RTP packet size Specify whether to limit the size of RTP packets sent from the camera when using RTP to view camera images. Setting value: Unlimited(1500byte) Unlimited (1500 byte) Limited(1280byte) Limited (1280 byte) Factory settings: Unlimited(1500byte) Normally, it is recommended that the [Unlimited(1500byte)] setting be used. Select [Limited(1280byte)] when the packet size of the used communication line is limited. For details on the maximum packet size of communication lines, consult your network administrator. 91

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

91
Web screen configurations
(continued)
DNS
Whether the DNS server address is to be acquired
automatically (Auto) or manually (Manual) is input here.
If “Manual” has been selected, the DNS settings must be
established.
If “Auto” is selected when the DHCP function is going
to be used, the DNS server address is acquired
automatically.
For further details, consult your system administrator.
Setting value:
Auto, Manual
Factory settings:
Auto
Primary server address
Secondary server address
Input the IP address of the DNS server if the “Manual”
setting has been selected for “DNS”.
For details on the IP address of the DNS server, consult
your system administrator.
z
IPv6 network
Manual
Enable or disable manual configuration of the IPv6
address.
Factory settings:
Off
IP address(IPv6)
When [Manual] is set to [On], the IPv6 address must be
entered manually.
Be sure to enter an address unique from other devices.
When connecting to the manually specified IP
address through a router, use an IPv6-compatible
router, and enable the automatic configuration
function for the IPv6 address. Be sure to configure
an IPv6 address that includes the prefix information
provided by the IPv6-compatible router. For details,
refer to the operating instructions for the router.
Note
Default gateway
When [Manual] is set to [On] for [IPv6 network], enter the
default gateway for the unit’s IPv6 network.
Factory settings:
blank
DHCPv6
Enable or disable use of the IPv6 DHCP function.
Configure the DHCP server so that the same IP address
is not configured for a personal computer that does not
use the DHCP function and other network cameras.
For details on server settings, consult your network
administrator.
Factory settings:
Off
Primary DNS server address
Secondary DNS server address
Enter the IPv6 address of the DNS server.
For details on the IPv6 address of the DNS server, consult
your system administrator.
z
Common (to IPv6/IPv4)
HTTP port
Port numbers are allocated separately.
Setting range:
1 to 65535
The following port numbers are used by the unit so they
cannot be used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162,
443, 554, 995, 10669, 10670, 59000 to 61000
Factory settings:
80
Max RTP packet size
Specify whether to limit the size of RTP packets sent from
the camera when using RTP to view camera images.
Setting value:
Unlimited(1500byte)
Unlimited (1500 byte)
Limited(1280byte)
Limited (1280 byte)
Factory settings:
Unlimited(1500byte)
Normally, it is recommended that the
[Unlimited(1500byte)] setting be used.
Select [Limited(1280byte)] when the packet size of the
used communication line is limited. For details on the
maximum packet size of communication lines, consult