How to install and connect the unit Be absolutely sure to read through the "Read this first!" (page 5) and "Installation precautions" (pages 6 to 7). The procedure given here is for the kind of installation where the unit is suspended from an overhead surface, but the same steps are followed for a stand-alone installation. If the ceiling panel is not strong enough to bear the unit's weight, use the kind of mount bracket that is supported by anchor bolts between the concrete ceiling and ceiling panel. The unit supports the WV‑Q105A direct ceiling mount bracket which is used solely for combination cameras. Use this bracket to install the unit. (See page 12.) In a case like this, the holes (ø 60 mm [ø 2-3/8 inches]) for installing the direct ceiling mount bracket on the ceiling must be drilled in the ceiling panel. It is also recommended that you provide an inspection space or opening for access purposes in the area near where the equipment is installed in order to facilitate installation and the wiring connections work. See page 36 for details of the accessories. 1 Check the mounting space. ●● Refer to the illustration, and determine where the unit is to be installed and in which direction it should be mounted. Factor in the unit mounting area and include space for the wires extending from its rear panel. ●● The asterisk () in the illustration marks the position and dimensions of the hole for mounting the mount bracket. Through-hole for cable ø 40 (ø 1-9/16) [reference] Unit: mm (inch) Hole for mounting the main unit mounting screw Hook for mounting the drop-prevention wire Unit mounting area Mount bracket 130 (5-1/8) (Space for the wires from the rear panel) 65 (2-9/16) 77 (3-1/32) 90 (3-17/32) 290 (11-7/16) or more (Space for the wires) () Holes for mounting the mount bracket: ø 4.5 x 4 () 46 (1-13/16) 78 (3-1/16) 80 (3-5/32) Hole for checking the positioning () 83.5 (3-9/32) 156 (6-1/8) 160 (6-5/16) Hole for installing the WV‑Q105A direct ceiling mount bracket [ø 60 (ø 2-3/8)] The front panel of the unit on this side Notes ●● Make connections for each cable within the ceiling beforehand, and pass the cables through a cable-routing hole in preparation for making connections for and installing the unit. ●● For a power outlet which is used on the ceiling, be absolutely sure to take measures to deal with the tracking that may be caused by the accumulation of dust and other foreign matter. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

8
How to install and connect the unit
Be absolutely sure to read through the “Read this first!” (page 5) and “Installation precautions” (pages 6 to 7).
The procedure given here is for the kind of installation where the unit is suspended from an overhead surface, but the same
steps are followed for a stand-alone installation.
If the ceiling panel is not strong enough to bear the unit’s weight, use the kind of mount bracket that is supported by
anchor bolts between the concrete ceiling and ceiling panel. The unit supports the WV-Q105A direct ceiling mount
bracket which is used solely for combination cameras. Use this bracket to install the unit. (See page 12.)
In a case like this, the holes (ø 60 mm [ø 2-3/8 inches]) for installing the direct ceiling mount bracket on the ceiling
must be drilled in the ceiling panel.
It is also recommended that you provide an inspection space or opening for access purposes in the area near where
the equipment is installed in order to facilitate installation and the wiring connections work.
See page 36 for details of the accessories.
1
Check the mounting space.
Refer to the illustration, and determine where the unit is to be installed and in which direction it should be mounted.
Factor in the unit mounting area and include space for the wires extending from its rear panel.
The asterisk (
) in the illustration marks the position and dimensions of the hole for mounting the mount bracket.
130 (5-1/8)
(
) 83.5 (3-9/32)
156 (6-1/8)
160 (6-5/16)
78 (3-1/16)
65 (2-9/16)
80 (3-5/32)
77 (3-1/32)
90 (3-17/32)
(
) 46 (1-13/16)
(Space for the wires from the
rear panel)
290 (11-7/16) or more
(Space for the wires)
Hole for checking
the positioning
The front panel of the unit on this side
Unit: mm (inch)
Mount bracket
Hook for mounting the
drop-prevention wire
Unit mounting area
Through-hole for cable
ø 40 (ø 1-9/16) [reference]
(
) Holes for mounting the
mount bracket: ø 4.5 x 4
Hole for mounting the main
unit mounting screw
Hole for installing the WV-Q105A
direct ceiling mount bracket
[ø 60 (ø 2-3/8)]
Make connections for each cable within the ceiling beforehand, and pass the cables through a cable-routing hole in
preparation for making connections for and installing the unit.
For a power outlet which is used on the ceiling, be absolutely sure to take measures to deal with the tracking that may
be caused by the accumulation of dust and other foreign matter.