Panasonic CF-29CRKGZKM Service Manual - Page 41

Setting the TP PCB, View

Page 41 highlights

7.2.9. Setting the TP PCB 1. Fix the TP PCB using the two Screws. No1, No2 2. Connect the three Cables to the three Connectors on the TP PCB (CN800, CN801, CN803). Note: Tighten the Screws in the numbered order (No1, No2). Screws : DRHM0002ZA Connector CN801 :No1 :No2 Connector CN800 Connector CN803 TP PCB to Connector (CN801) n Attaching the Cable Sheet, Insulation Sheet and the Sheet 1. Attach the Sheet and Insulation Sheet on the TP PCB. 2. Attach the Cable Sheet on the Touch Pad FPC. View "A" Top Cabinet LED FFC Sheet TP PCB View "A" to Connector (CN800) to Connector (CN803) Sheet Top Cabinet 0~1mm 0~0.5mm 0~1mm LED FFC Connectors TP PCB 1~2mm Touch Pad FPC Cable Sheet Insulation Sheet 0~2mm Rib of the Top Cabinet 0~1mm 7-23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

7-23
7.2.9.
Setting the TP PCB
1. Fix the TP PCB using the two Screws<c>. No1, No2
2. Connect the three Cables to the three Connectors on the
TP PCB (CN800, CN801, CN803).
Note:
Tighten the Screws in the numbered order (No1, No2).
Screws <c>:
DRHM0002ZA
n
Attaching the Cable Sheet, Insulation Sheet and the Sheet
1. Attach the Sheet and Insulation Sheet on the TP PCB.
2. Attach the Cable Sheet on the Touch Pad FPC.
<c>
:No1
<c>
:No2
TP PCB
to Connector
(CN800)
to Connector
(CN801)
Connector CN801
Connector CN800
Connector CN803
to Connector
(CN803)
Insulation Sheet
Sheet
Top Cabinet
Touch Pad FPC
Cable Sheet
TP PCB
LED FFC
Sheet
LED FFC
Rib of the Top Cabinet
Top Cabinet
TP PCB
Connectors
View "A"
View "A"
0~0.5mm
1~2mm
0~2mm
0~1mm
0~1mm
0~1mm