Panasonic PT-D6000ULK Operating Instructions - Page 28
Monitor Lamp indicators, Managing the indicated problems
UPC - 791871111871
View all Panasonic PT-D6000ULK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Monitor Lamp indicators Managing the indicated problems Indicators Power indicator Lamp1 (LAMP1) indicator Lamp2 (LAMP2) indicator Temperature (TEMP) indicator Filter (FILTER) indicator STANDBY(RED)/ ON(GREEN) LAMP TEMP FILTER STANDBY(RED)/ ON(GREEN) LAMP TEMP FILTER If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow. 1. Confirm the status of all indicators and projector, and switch off the projector in proper way. 2. Find out the cause of the problem by status of each indicator. 3. Follow the instruction for each indication below and solve the problem. 4. Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer. NOTE: • If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center. J LAMP1/LAMP2 indicator Lamp indication Lighting in red Blinking in red once Blinking in red 3 times Information Check point Remedial measure • Did you notice a "REPLACE • This lamp monitor lights up when the lamp Indicates the time for LAMP" message on the screen unit used hours have reached 1 800 hours. replacing the lamp unit when turning on the projector Request the dealer to replace the lamp unit. power supply? • Check the lamp unit • Install the lamp unit. Lamp unit is not installed. compartment. • When lamp unit is installed and still having the indicator lights, contact to the dealer. • Did you turn the power back on • Wait until the lamp has cooled off, and then immediately after turning it off? turn on the power. Error is detected in the lamp circuit. • Some error has arisen in the lamp circuit. • Turn off the POWER switch of the projector in proper way and contact the dealer. • Check for fluctuation (or drop) in the source voltage. J TEMP indicator Lamp indication Lighting in red Blinking in red twice Blinking in red 3 times Information Check point Remedial measure Warm-up status High temperature inside. (WARNING) High temperature inside. (Standby condition) Cooling fan has been stopped. • Did you turn on the power when • Wait about 5 minutes in the current status. the ambient temperature was • Install the unit in a location having an lower than approx. 0 °C (32 °F)? ambient temperature from 0 °C (32 °F) - 45 °C (113 °F). • Check the ventilation port is • Remove the object that is blocking the blocked. ventilation port. • Is the room air temperature too • Move the projector to a temperature of 0 °C high? (32 °F) - 45 °C (113 °F) and the humidity of • Was the temperature warning 20 % to 80 % (no condensation). indication displayed? • Turn off the POWER switch of the projector in proper way and contact the dealer. • Turn off the POWER switch of the projector in proper way and contact the dealer. Maintenance ENGLISH - 28