Panasonic PT-D6000ULK Operating Instructions - Page 29
Monitor Lamp indicators, FILTER indicator, ENGLISH - 29
UPC - 791871111871
View all Panasonic PT-D6000ULK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Monitor Lamp indicators J FILTER indicator The FILTER indicates the Auto Cleaning Filter (ACF) unit status. Lamp indication Information Check point Remedial measure Lighting in red • Check the REMAINING FILTER • Replace the ACF unit. The ACF unit has run out. of STATUS in PROJECTOR SETUP menu. Blinking in red Lighting in orange Blinking in orange The ACF unit is not installed.*1 The ACF unit remains few. The remaining use time of the ACF unit is approximately 200 hours.*2 The ACF unit cannot operate properly. • Check the ACF unit compartment. • Replace the ACF unit. • Check the REMAINING FILTER • Request the dealer to purchase the new of STATUS in PROJECTOR ACF unit. SETUP menu. • Is foreign object blocking the ACF unit operation? • Remove the foreign object from the ACF unit. • When the foreign object still remained, contact the dealer. *1. When the ACF unit is not installed, displays "THE AIR FILTER HAS NOT BEEN INSTALLED PROPERLY." message and power off with the indicator blinking in red. *2. 200 hours is the roughly guided time. NOTE: • When the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up. • When the ACF unit is operating, operational sound may be heard. • In a dusty environment, the guided remaining use time will be shorter. Contact the dealer to purchase the new ACF unit earlier. • If using the projector at high elevations 1 400 - 2 700 m (4 593 - 8 858 ft) sea level and HIGH ALTITUDE MODE in PROJECTOR SETUP menu is OFF, it may cause malfunction of the ACF unit. Maintenance ENGLISH - 29