ViewSonic CD4220 User Guide - Page 57

Remote Control Pass-through mode

Page 57 highlights

6.3 Remote Control Pass-through mode When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by "CR") in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: "+Volume" will not change the volume in the LCD but only sends "+Volume" code to PC over the RS232 port. Remote Control pass-through packet format from LCD monitor to PC(ASCII) Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 MSB LSB 00D Bytes order 1 2 3 4 Example: Remote Control pass-through when "Menu" key is pressed (1A) Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 1 A 00D Bytes order 1 2 3 4 Example: Remote Control pass-through when key "1" is pressed (01) Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 0 1 00D Bytes order 1 2 3 4 Example: Remote Control pass-through when "OK" key is pressed (1F) Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 1 F 00D Bytes order 1 2 3 4 Key Size Volume Up (+) Volume Down (-) Mute POWER INPUT PIP ON/OFF MENU Up Down Left(-) Right(+) SET PIP INPUT PIP CHANGE PICTURE MODE AUDIO INPUT SCREEN SAVER GAMMA SCREEN SAVER BRIGHTNESS DISPLAY AUTO SETUP EXIT Code (HEX) 0F 10 11 12 15 16 17 1A 1B 1C 1D 1E 1F 00 00 00 00 00 00 00 00 00 ViewSonic CD4220 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

ViewSonic
CD4220
55
6.3
Remote Control Pass-through mode
When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three
bytes packet (followed by “CR”) in response to RCU button activation.
Note, that in this mode the RCU
shall have no effect on the monitor function.
For example: “+Volume” will not change the volume in the
LCD but only sends “+Volume” code to PC over the RS232 port.
Remote Control pass-through packet format from LCD monitor to PC(ASCII)
Name
Length
RCU-Code1
RCU-Code2
CR
Byte Count
3
MSB
LSB
00D
Bytes order
1
2
3
4
Example: Remote Control pass-through when “Menu” key is pressed (1A)
Name
Length
RCU-Code1
RCU-Code2
CR
Byte Count
3
1
A
00D
Bytes order
1
2
3
4
Example: Remote Control pass-through when key “1” is pressed (01)
Name
Length
RCU-Code1
RCU-Code2
CR
Byte Count
3
0
1
00D
Bytes order
1
2
3
4
Example: Remote Control pass-through when “OK” key is pressed (1F)
Name
Length
RCU-Code1
RCU-Code2
CR
Byte Count
3
1
F
00D
Bytes order
1
2
3
4
Key
Code (HEX)
Size
0F
Volume Up (
+
)
10
Volume Down (
-
)
11
Mute
12
POWER
15
INPUT
16
PIP ON/OFF
17
MENU
1A
Up
1B
Down
1C
Left(-)
1D
Right(+)
1E
SET
1F
PIP INPUT
00
PIP CHANGE
00
PICTURE MODE
00
AUDIO INPUT
00
SCREEN SAVER GAMMA
00
SCREEN SAVER BRIGHTNESS
00
DISPLAY
00
AUTO SETUP
00
EXIT
00