Yamaha MX61 Reference Manual - Page 66
Remote, Performance, Pattern
View all Yamaha MX61 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Performance Song/Pattern File Utility Remote Parameter CtrlReset (Controller Reset) Description Determines the status of the controllers (Modulation Wheel, Foot Controller, Knobs, etc.) when switching between Voices. When this is set to "hold," the controllers are kept at the current setting. When this is set to "reset," the controllers are reset to the default states (below). Settings: hold, reset If you select "reset," the controllers will be reset to the following states/positions. As for controllers that are not actually available on the instrument itself (for example, After Touch, Ribbon Controller, and Breath Controller), these functions can be enabled by transmitting the corresponding MIDI control number from an external MIDI controller. Pitch Bend Center Ribbon Controller Center Modulation Wheel Minimum Breath Controller Maximum After Touch Minimum Assignable Function off Foot Controller Maximum Expression Maximum Footswitch off Utility General MIDI Controllers Remote Utility Job QuickSeup Factory Set Version MIDI Sync ClockOut (MIDI Clock Out) SeqCtrl (Sequencer Control) BasicCh (Basic Channel) DeviceNo. (Device number) RcvBulk (Receive Bulk switch) BulkInterval (Bulk Dump Interval) Determines whether Song/Pattern/Arpeggio playback will be synchronized to the instrument's internal clock or an external MIDI clock. Settings: internal, external, auto internal..... Synchronization to internal clock. You can use this setting when this tone generator is to be used alone or as the master clock source for other equipment. external.... Synchronization to a MIDI clock received from an external MIDI instrument via MIDI. Use this setting when an external sequencer is to be used as the master. auto.......... When MIDI clock is transmitted continuously from an external MIDI device or computer, the internal clock of the MX49/MX61 is automatically disabled and the MX49/MX61 is synchronized with the external clock. When MIDI clock is not transmitted from the external MIDI device or computer, the internal clock of the MX49/MX61 continues to run in sync with the latest received tempo of the external MIDI device or computer (DAW software). This setting is useful when you wish to alternate between external clock and internal clock. NOTE When setting the MX49/MX61 so that Song/Pattern/Arpeggio playback is synchronized to an external MIDI clock, make sure to set the devices so that the MIDI clock from the DAW software/ external MIDI device is properly transmitted to the MX49/MX61. Determines whether MIDI clock (F8) messages will be transmitted via the MIDI OUT/USB terminal. Settings: off, on Determines whether or not Sequencer Control signals-start, continue and stop-will be received and/or transmitted via MIDI. Settings: off, in, out, in/out off Not transmitted/recognized. in Recognized, but not transmitted. out Transmitted, but not recognized. in/out........ Transmitted/recognized. Determines the MIDI transmit/receive channel for an entire Performance. Settings: 1 - 16, off NOTE The MIDI transmit/receive channel for Part 1-16 is fixed to 1 - 16 regardless of the "BasicCh" setting. Determines the MIDI Device Number. This number must match the Device Number of the external MIDI device when transmitting/receiving bulk data, parameter changes or other System Exclusive messages. Settings: 1 - 16, all, off Determines whether or not Bulk Dump data can be received. Settings: protect (not received), on (received) Determines the interval time of the Bulk Dump transmission when the Bulk Dump function is used or a Bulk Dump Request is received. Settings: 0 - 900 ms MX49/MX61 Reference Manual 66