    Omni 56K Plus Series DATA/FAX Modem User's Guide Version 1.0.0 July 2004
  • ZyXEL omni.net Plus | User Guide - Page 2
    Omni 56K Plus Series User's Guide Copyright Copyright © 2004 by ZyXEL Communications Corporation. The contents of this publication may not be reproduced in any part or as a whole, transcribed, stored in a retrieval system, translated into any
  • ZyXEL omni.net Plus | User Guide - Page 3
    Omni 56K Plus Series User's Guide frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference equipment. Certifications 1. Go to www.zyxel.com. 2. Select your product from the drop-down list box on the ZyXEL home page to go to that product
  • ZyXEL omni.net Plus | User Guide - Page 4
    Omni 56K Plus Series User's Guide ZyXEL Limited Warranty ZyXEL character to the purchaser. To obtain the services of this warranty, contact ZyXEL's Service Center for your Return Material Authorization number zyxel.com for free future product updates and information. iv ZyXEL Limited Warranty
  • ZyXEL omni.net Plus | User Guide - Page 5
    Omni 56K Plus Series User's Guide Customer Support When you contact your customer support representative please have the following information ready: Please have the following information ready when you contact customer support. • Product model and serial number. • Warranty Information. • Date
  • ZyXEL omni.net Plus | User Guide - Page 6
    56K Plus Series User's Guide Table of Contents Copyright ...ii Federal Communications Commission (FCC) Interference Statement iii ZyXEL Limited Warranty ...iv Customer Support...v Table of Contents ...vi List of Tables ...vii Preface...viii Chapter 1 Introduction...1-1 1.1 ZyXEL Omni 56K Plus modem
  • ZyXEL omni.net Plus | User Guide - Page 7
    Omni 56K Plus Series User's Guide List of Tables Table 2-1 Hardware Specification ...2-1 Table 2-2 Firmware Specification ...2-1 Table 2-3 Feature Description ...2-4 Table 2-4 Physical Layer Capacity...2-4 Table 2-5 Different Ring Types in Register S40 2-8 Table 2-6 Fax Physical Layer Capacity 2-
  • ZyXEL omni.net Plus | User Guide - Page 8
    This manual may refer to the Omni 56K USB Plus and/or Omni 56K COM Plus modems as the Omni 56K Plus. Related Documentation Support Disk Refer to the included CD for support documents. Quick Start Guide The Quick Start Guide is designed to help you quickly learn how to install your Omni 56K USB Plus
  • ZyXEL omni.net Plus | User Guide - Page 9
    Omni 56K Plus Series User's Guide • Mouse action sequences are denoted using a comma. For example, "click the Apple icon, Control Panels and then Modem" means first click the Apple icon, then point your mouse pointer to Control Panels and then click Modem. • For brevity's sake, we will use "e.g." as
  • ZyXEL omni.net Plus | User Guide - Page 10
  • ZyXEL omni.net Plus | User Guide - Page 11
    Omni 56K Plus Series User's Guide Chapter 1 Introduction This chapter introduces you to the features and specifications for the ZyXEL Omni 56K USB Plus and Omni 56K COM Plus modems. 1.1 ZyXEL Omni 56K Plus modem Overview The Omni 56K USB Plus or Omni 56K COM Plus is an analog Data/Fax modem used for
  • ZyXEL omni.net Plus | User Guide - Page 12
  • ZyXEL omni.net Plus | User Guide - Page 13
    Requirements Operating Requirements Weight Dimensions SPECIFICATION DESCRIPTION 9V AC (Omni 56K COM Plus only) Temperature: 0° C to 40° C Humidity: 20 to 90 % (non-condensing) Omni 56K COM Plus: 194.6 g Omni 56K USB Plus: 170.4 g 112.5 mm (W) x 29 mm (H) x 106 mm (L) 2.2 Firmware Specifications
  • ZyXEL omni.net Plus | User Guide - Page 14
    Omni 56K Plus Series User's Guide Link layer Flow Control Command set Diagnostics Fax Voice Table 2-2 Firmware Specification MNP 3-4 MNP 5 V42 V42bis V.44 Hardware flow control: RTS/CTS Software flow control: XON/XOFF Full AT command set Dialing type: DTMF/Pulse Power-on self-test Analog loop-back
  • ZyXEL omni.net Plus | User Guide - Page 15
    Basic AT Command set ZyXEL AT Command set Extended AT& Command Set Extended AT* Command Set Extended AT# Command Set IS101 Voice Command set For more information on detailed command sets, please refer to Chapter 4. 2.4 Capability The data/fax/voice feature of the Omni 56K Plus is described as below
  • ZyXEL omni.net Plus | User Guide - Page 16
    Omni 56K Plus Series User's Guide FEATURE Data Fax Voice Table 2-3 Feature Description DESCRIPTION 2W Dial-Up Line Multi-auto/ V.92/V.90/V.34/V.32bis/V.32/V.22bis/V.22/V.21/Bell 103 Hardware/Software Flow Control Error Control/Data Compression ZyXEL AT Command Set External Plug and Play for
  • ZyXEL omni.net Plus | User Guide - Page 17
    free by detecting and re-transmitting erroneous data. The Omni 56K Plus modems support both MNP and V.42 error control protocols. The MNP protocol was an industry standard developed and licensed by Microcom, Inc. Omni 56K Plus modems support level 4 and 3 error control protocols, commonly denoted as
  • ZyXEL omni.net Plus | User Guide - Page 18
    Plus Series User's Guide 2.5.6 Data Compression In the modem, the data compression is activated in an attempt to reduce the number of bits actually sent. The receiving modem applies these techniques in reverse to recover the actual data from the compressed data stream. Omni 56K Plus modems support
  • ZyXEL omni.net Plus | User Guide - Page 19
    Omni 56K Plus Series User's Guide TIME: CALLER NUMBER: or CALLER NAME: RING NUMBER: OUT_OF_AREA REASON FOR NO NAME: PRIVACY RING The last CND message that the modem received can be displayed by using the AT*T command. Specifications and Function Description 2-7
  • ZyXEL omni.net Plus | User Guide - Page 20
    Omni 56K Plus Series User's Guide Setting S48.0=1 will cause the modem to report CND information in its ASCII coded hexadecimal raw data format. The DTE software is supported before service that may be offered by your phone company. Check your phone company for availability. With this service
  • ZyXEL omni.net Plus | User Guide - Page 21
    Omni 56K Plus Series User's Guide security is used when the remote modem is also a ZyXEL modem; type 2 security is used when the remote modem is any other brand of modem. With the type 1 connection, the dial-in (remote) modem will send in its supervisor password for checking at the initial
  • ZyXEL omni.net Plus | User Guide - Page 22
    Omni 56K Plus Series User's Guide Before the security type or level can be changed, the modem requires the modem relieves the computer fax software of the T.30 protocol handling. You modem allows for fax speeds up to 14400 bps when transmitting to a fax machine which complies with the V.17 fax
  • ZyXEL omni.net Plus | User Guide - Page 23
    Omni 56K Plus Series User's Guide quality. This algorithm can also be used to reduce the speech data rate to 1/3 or 1/4 of the original rate, but with voice quality degradation. Only 4-bit ADPCM is used in the Omni 56K Plus. Specifications and Function Description 2-11
  • ZyXEL omni.net Plus | User Guide - Page 24
  • ZyXEL omni.net Plus | User Guide - Page 25
    Omni 56K Plus Series User's Guide Chapter 3 Result Codes A result code is the command response or the connect message to the DTE. The format of the result code is dependent on
  • ZyXEL omni.net Plus | User Guide - Page 26
    Omni 56K Plus Series User's Guide Table 3-1 Result Codes Result Code for ATV0 ATV1 31 CONNECT624000 32 CONNECT124800 33 CONNECT 62400 34 CONNECT 41600 35 CONNECT 31200 36 CONNECT 24960 37
  • ZyXEL omni.net Plus | User Guide - Page 27
    Omni 56K Plus Series User's Guide COMPRESSION: Compression Level CONNECT DTE Speed X5: CONNECT DTE Speed/Protocol Rx Rate/Error control level X6: CONNECT Rx Rate/ARQ X7: CONNECT Rx Rate/
  • ZyXEL omni.net Plus | User Guide - Page 28
  • ZyXEL omni.net Plus | User Guide - Page 29
    Omni 56K Plus Series User's Guide Chapter 4 Command Sets This chapter lists the command set the Omni 56K Plus supports. These commands include data command sets, fax . +++ Escape sequence code, entered in data state, wait for modem to return to on line command mode. All the Following Commands
  • ZyXEL omni.net Plus | User Guide - Page 30
    Omni 56K Plus Series User's Guide COMMAND DL DSn En Hn In Ln Mn Nn O O1 Qn Sr.b=n Sr .1-3 Return to on-line state. Force modem to request a retrain. Result code displayed. S23.7 Modem returns result code. Modem does not return result code. Modem returns result code but quiet after answering
  • ZyXEL omni.net Plus | User Guide - Page 31
    Omni 56K Plus Series User's Guide COMMAND Sr? T UPX Vn Xn Zn $ &$ *$ +++ Table 4-2 AT Command Sets B0 &B1 * &C0 &C1 * &D0 &D1 &D2 * &D3 FUNCTION & DESCRIPTION Data rate, terminal-to-modem. (DTE/DCE) DTE rate follows connection rate. (See also S44.6) DTE/DCE rate fixed at DTE setting (See
  • ZyXEL omni.net Plus | User Guide - Page 32
    Omni 56K Plus Series User's Guide COMMAND &Gn &Hn & . Hardware (CTS/RTS) flow control. Software (XON/XOFF) flow control. Modem error control and data compression. No error , V.34bis, V.32bis, V.32, V.22bis, V.22 and Bell 212A, G3 Fax V.17/V.29/V.27ter. V.32 9600T/9600/7200T/4800 V.32 9600/7200/4800
  • ZyXEL omni.net Plus | User Guide - Page 33
    Omni 56K Plus Series User's Guide COMMAND &Pn &Rn Table 4-3 Extended AT& Command Sets OPTIONS &N65 &N66 &N67 &N68 &N69 &N70 &N71 &N72 &N73 &N99 &N98 &N97 &N96 &N95 &N94 &N93 &
  • ZyXEL omni.net Plus | User Guide - Page 34
    Omni 56K Plus Series User's Guide COMMAND &Sn &Tn &Vn &Wn &Yn &Z? &Zn=s Table 4-3 Extended AT& Command Sets OPTIONS according to CCITT (ITU-TSS). (See also S41.5, S44.4) Modem testing. S16 Terminate test in progress. Initiate Analog Loop-back (ALB) test. Initiate Local Digital Loop-back (LDL
  • ZyXEL omni.net Plus | User Guide - Page 35
    Omni 56K Plus Series User's Guide COMMAND *Dn *En *Gn *HS *Hn *In *Pn *Qn Table 4-4 Extended AT* Command Sets OPTIONS FUNCTION & DESCRIPTION REF. *C3 8-bit character length n=0-3 Set default dial pointer at telephone directory location 'n.' S29 *D0 * (See also S35.4 and S38.0) Modem
  • ZyXEL omni.net Plus | User Guide - Page 36
    Omni 56K Plus Series User's Guide COMMAND *T *V Table 4-4 Extended AT* Command Sets OPTIONS *Q3 FUNCTION report of modem status in escape state 4.2 Fax command sets 4.2.1 Service Class 1 Commands Table 4-6 Service Class 1 Commands COMMAND +FCLASS=n DESCRIPTION Service Class Identification
  • ZyXEL omni.net Plus | User Guide - Page 37
    Omni 56K Plus Series User's Guide VALUE 74 96 97 98 121 122 145 146 Table 4-7 The Value of Parameters MODULATION V.17 short train V.29 V.17 V.17 short train V.17 V.17 short train V.17 V.17 short train SPEED 7200 9600 9600 9600 12000 12000 14400 14400 4.2.2 Service Class 2 Commands The
  • ZyXEL omni.net Plus | User Guide - Page 38
    Omni 56K Plus Series User's Guide Table 4-9 Supported Commands (per TIA PN2388 8/20/90) COMMAND DESCRIPTION Only check 1D phase C data. Check both 1D and 2D phase C data. +FCR=n "Capability to receive" parameter
  • ZyXEL omni.net Plus | User Guide - Page 39
    Omni 56K Plus Series User's Guide COMMAND Table 4-9 Supported Commands (per TIA PN2388 8/20/90) DESCRIPTION VALUE +FDR +FDT=df,vr,wd, ln + end of document. Regular fax abort command. Local ID string parameter. Flow control options: No flow control. Set XON/XOFF software flow control. Set CTS/RTS
  • ZyXEL omni.net Plus | User Guide - Page 40
    Omni 56K Plus Series User's Guide Table 4-9 Supported Commands (per TIA PN2388 8/20/90) COMMAND DESCRIPTION VALUE Page bad; : Disable polling. n=0 Enable polling. n=1 All other +F commands are not supported, but the modem will respond OK. In many cases this means "don't care". Table 4-10
  • ZyXEL omni.net Plus | User Guide - Page 41
    . Service Class Identification and Control +FMI? Identify DCE Manufacturer +FMM? Identify DCE +FMR? Identify DCE Revision +FCC=vr,br,wd,ln,df,ec,bf,st Establish DCE Capabilities Vertical Resolution Bit Rate VALUE n=0,1,2.0,8;refer to the +FCLASS Class 1 command ZyXEL Omni 56K Plus Vx
  • ZyXEL omni.net Plus | User Guide - Page 42
    Omni 56K Plus Series User's Guide Table 4-11 Service Class 2.0 Commands COMMAND DESCRIPTION Page Width Page Length Data Compression Format Error Correction Binary File Transfer Minimum Scan Time/Line +FIS=vr,br,wd,ln,
  • ZyXEL omni.net Plus | User Guide - Page 43
    FCR=n +FCQ=, +FRQ=pql,cbl Omni 56K Plus Series User's Guide Table 4-11 Service Class 2.0 Commands DESCRIPTION Procedure Interrupt parameter Page Transfer is requested. n=0:No flow control n=1:Sets XON/ XOFF software flow control n=2:Sets CTS/RTS hardware flow control n=0:Automatic DTE
  • ZyXEL omni.net Plus | User Guide - Page 44
    Omni 56K Plus Series User's Guide COMMAND +FAA=n +FCT=n +FMS=n +FBS? Table 4-11 Service Class 2.0 Commands DESCRIPTION Adaptive Answer Mode Phase C Timeout Minimum Phase C Speed Buffer Size VALUE n=0:Answers as set by +FCLASS n=1:Answers and autodetermines the call type. n=0-
  • ZyXEL omni.net Plus | User Guide - Page 45
    Omni 56K Plus Series User's Guide to the Telephone line. The local phone is provided with power. The modem can record/play through the local telephone line. +VRA Ring back goes detection. Unit: 0.1 second +VSM Selection of compression method 4;ZyXEL ADPCM; 4,9600 4 Bit;(9600) IMA 4 bit ADPCM.
  • ZyXEL omni.net Plus | User Guide - Page 46
    Omni 56K Plus Series User's Guide Table 4-12 Voice AT Commands COMMAND FUNCTION +VTS= x,x... DTMF Tone Generation Answer Tone detected Busy detected Calling Tone detected Dial tone detected European Data Modem Calling Tone detected Bell Answer Tone detected The local handset on hook Quiet
  • ZyXEL omni.net Plus | User Guide - Page 47
    Omni 56K Plus Series User's Guide 4.6 S-Register Descriptions In most bit-mapped S-registers, the 2 2 Capture modem manufacturer information during V.42 handshake, can be displayed at ATI2 line if available ('Flash' or ' ZyXEL' stands for ZyXEL connection) S14= bit
  • ZyXEL omni.net Plus | User Guide - Page 48
    Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers " Digital Loop-back with self-test in process. 8 8 Analog Loop back with self-test in progress. S17= bit dec rate value settings (n) the same as S20 S19= dec hex Modem connection mode, same 0-99 0-63 Setting value as 'AT&Nn
  • ZyXEL omni.net Plus | User Guide - Page 49
    Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers "ATSn=x" S20=15 are supported by auto speed detection. S21= bit dec hex Bit non-error control connection when modem error control handshake fails. 1 1 Drop connection when modem error control handshake fails.
  • ZyXEL omni.net Plus | User Guide - Page 50
    Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers "ATSn=x" COMMAND BIT DEC HEX FUNCTION .7) 64 40 Display result code in verbose format. (Default) 7 0 0 Modem returns result code. (Default) 128 80 Modem does not return result code. (see also S40.1) S24= bit dec hex Bit
  • ZyXEL omni.net Plus | User Guide - Page 51
    Omni 56K Plus Series User's Guide is set to 4 ms. S27= bit dec hex Bit mapped register. +156 0-2 Modem error control. 0 0 No error control. &K0 1 1 MNP4 + MNP3 (see Hardware (RTS/CTS) flow control. (Default) &H3* 32 20 Software (XON/XOFF) flow control. &H4 40 28 Reserved. &H5
  • ZyXEL omni.net Plus | User Guide - Page 52
    Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers "ATSn=x" COMMAND BIT Fax mode DTE shifting: +FCON at current DTE rate, shift to 19,200 when entering into the next phase 5 32 20 Disable srambler/descrambler in V.26bis mode. * Enables compatibility with older V.26bis modems
  • ZyXEL omni.net Plus | User Guide - Page 53
    Omni 56K Plus Series User's Guide on EIA-232D interface. 4 16 10 In X2-X7 setting, modem waits for S6 seconds before dialing and ignores dial tone detection. 5 sequence code in answer mode. 4 16 10 Disable V.17 14,400 Fax in calling mode, no effect to answering mod. 5 32 20 Disable
  • ZyXEL omni.net Plus | User Guide - Page 54
    Omni 56K Plus Series User's Guide Table 4-16 Extended S-Registers "ATSn=x" COMMAND BIT DEC hex Bit-mapped register +006 7 0 0 For cellular mode only. Modem is installed in office * (Default) 128 80 For cellular mode only. Modem is connected to a mobile phone S52= bit dec hex Bit-mapped
  • ZyXEL omni.net Plus | User Guide - Page 55
    Omni 56K Plus Series User's Guide Chapter 5 Firmware Upgrade You can upgrade modem firmware either by using the software utility provided in the CD-ROM that comes with your modem package, or by terminal emulation program such as Bitware or Hyperterminal. To obtain the latest firmware version, please
  • ZyXEL omni.net Plus | User Guide - Page 56
    or Hyperterminal (Windows). For more information on how to install Bitware on your computer, please refer to the Quick Start Guide that comes with your modem package. 5.2.1 Upgrading Using Bitware Example 1. Turn on your computer and connect your modem to the computer. For the Omni 56K COM Plus, you
  • ZyXEL omni.net Plus | User Guide - Page 57
    Omni 56K Plus Series User's Guide 5. Type in atupx it will show a message in the next screen. Firmware Upgrade 5-3
  • ZyXEL omni.net Plus | User Guide - Page 58
    Omni 56K Plus Series User's Guide 6. Be sure you have the new firmware file on hand, then enter Y. The terminal will response as shown next. Remember that you must decompress compressed (.
  • ZyXEL omni.net Plus | User Guide - Page 59
    Omni 56K Plus Series User's Guide 9. After the firmware upload process has completed, you can use the modem again. 5.2.2 Upgrading Using HyperTerminal Example 1. Open the HyperTerminal program in Windows. For example, in Windows 2000 click Start, Programs, Accessories, Communications, HyperTerminal
  • ZyXEL omni.net Plus | User Guide - Page 60
    Omni 56K Plus Series User's Guide 2. Enter a descriptive name and select an icon in the Connection Description screen. Click OK to display the Connect to screen. 3. Select the COM port to which the modem is connected. Click OK to continue. 4. In the COM Properties screen, click OK after
  • ZyXEL omni.net Plus | User Guide - Page 61
    Omni 56K Plus Series User's Guide 5. Type in atupx it will show a message in the next screen. Firmware Upgrade 5-7
  • ZyXEL omni.net Plus | User Guide - Page 62
    Omni 56K Plus Series User's Guide 6. Be sure you have the new firmware file on hand, then enter Y. The terminal will response as shown next. Remember that you must decompress compressed (.
  • ZyXEL omni.net Plus | User Guide - Page 63
    Omni 56K Plus Series User's Guide 8. Choose the Xmodem protocol. Type the firmware file's location, or click Browse to search for it. Then click Send. 9. After the firmware upload process has completed, you can use the modem again. Firmware Upgrade 5-9
  • ZyXEL omni.net Plus | User Guide - Page 64
    Omni 56K Plus Series User's Guide 5-10 Firmware Upgrade
  • ZyXEL omni.net Plus | User Guide - Page 65
    2-1 Omni 56K Plus Series User's Guide Index I i.e See Syntax Conventions Internet Security Appliance viii ITU-T T.30 Fax Protocol 2-10 K Key Features 1-1 N Notice iii O Online Registration iv P Packing List Card viii Physical Layer Capability 2-4 Protocol Support 2-2 R Related
  • ZyXEL omni.net Plus | User Guide - Page 66
    Omni 56K Plus Series User's Guide Voice AT Commands 4-16 Voice Function 2-10 Voice IS-101 Command Set 2-10 Voice Shield DTE Commands 4-18 Voice Shield DTE Responses 4-18 W www.zyxel.com iv Z ZyXEL Limited Warranty Note iv ZyXEL website iv ii Index
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series
DATA/FAX Modem
User’s Guide
Version 1.0.0
July 2004