ZyXEL omni.net Plus User Guide - Page 47

S-Register Descriptions, S-Register default values may vary depending on the country.

Page 47 highlights

Omni 56K Plus Series User's Guide 4.6 S-Register Descriptions In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an asterisk. In some cases, default values are shown in the reference column preceded by +. Some bits are reserved for factory use and should not be changed. S-Register default values may vary depending on the country. Table 4-15 Basic S-Registers "ATSn=x" COMMAND S0= S1= S2= S3= S4= S5= S6= S7= S8= S9= S10= S11= FUNCTION & DESCRIPTION Sets the number of rings on which the modem will answer. 0 value disables auto-answer. Counts and stores number of rings from an incoming call. Defines escape code character, default '+' (43 dec.). A value of 128-255 disables the escape code. Defines ASCII Carriage Return. Defines ASCII Line Feed. Defines ASCII Backspace. A value of 128-255 disables the Backspace key's delete function. Sets the number of seconds the modem waits before dialing if 'X0' or 'X1' is selected. If a setting of 'X2,' 'X7' is selected, the modem will dial as soon as it detects a dial tone. This register also sets the time-out interval for the "W" dial modifier to wait for the dial tone. (See also S41b4) Sets duration, in number of seconds modem waits for a carrier. Sets duration, in seconds, for pause (,) option in Dial command and pause between command re-executions for Repeat (>) command. Sets duration, in tenths of a second of remote carrier signal before recognition. (Ignored if in non-FSK or half-duplex operation) Sets duration, in tenths of a second, modem waits after loss of carrier before hanging up. Sets duration and spacing, in milliseconds, of dialed Touch-Tones. +REF. +000 +000 +043 +013 +010 +008 +003 +060 +002 +006 +007 +070 Table 4-16 Extended S-Registers "ATSn=x" COMMAND BIT DEC HEX FUNCTION AND DESCRIPTION S13= bit dec hex Bit-mapped register. 1 2 2 Capture modem manufacturer information during V.42 handshake, can be displayed at ATI2 line if available ('Flash' or ' ZyXEL' stands for ZyXEL connection) S14= bit dec hex Bit-mapped register: 1 0 0 Grant Remote Digital Loop-back test request. 2 2 Deny Remote Digital Loop-back test request. (Default) S15= bit dec hex Bit-mapped register. REF. +000 +002 &T4 &T5* +066 Command Sets 4-19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
Command Sets
4-19
4.6
S-Register Descriptions
In most bit-mapped S-registers, the default bit value is 0. Non-0 default values are followed by an
asterisk. In some cases, default values are shown in the reference column preceded by +. Some bits are
reserved for factory use and should not be changed.
)
S-Register default values may vary depending on the country.
Table 4-15 Basic S-Registers "ATSn=x"
COMMAND
FUNCTION & DESCRIPTION
+REF.
S0=
Sets the number of rings on which the modem will answer.
0 value disables
auto-answer.
+000
S1=
Counts and stores number of rings from an incoming call.
+000
S2=
Defines escape code character, default ‘+’
(43 dec.). A value of 128-255
disables the escape code.
+043
S3=
Defines ASCII Carriage Return.
+013
S4=
Defines ASCII Line Feed.
+010
S5=
Defines ASCII Backspace. A value of 128-255 disables the Backspace key’s
delete function.
+008
S6=
Sets the number of seconds the modem waits before dialing if ‘X0’ or ‘X1’ is
selected. If a setting of ‘X2,’ ‘X7’ is selected, the modem will dial as soon as it
detects a dial tone. This register also sets the time-out interval for the “W” dial
modifier to wait for the dial tone. (See also S41b4)
+003
S7=
Sets duration, in number of seconds modem waits for a carrier.
+060
S8=
Sets duration, in seconds, for pause (,) option in Dial command and pause
between command re-executions for Repeat (>) command.
+002
S9=
Sets duration, in tenths of a second of remote carrier signal before recognition.
(Ignored if in non-FSK or half-duplex operation)
+006
S10=
Sets duration, in tenths of a second, modem waits after loss of carrier before
hanging up.
+007
S11=
Sets duration and spacing, in milliseconds, of dialed Touch-Tones.
+070
Table 4-16 Extended S-Registers "ATSn=x"
COMMAND
BIT
DEC
HEX
FUNCTION AND DESCRIPTION
REF.
S13=
bit
dec
hex
Bit-mapped register.
+000
1
2
2
Capture modem manufacturer information during V.42
handshake, can be displayed at ATI2 <Last
Speed/Protocol> line if available (‘Flash’ or ‘ ZyXEL’
stands for ZyXEL connection)
S14=
bit
dec
hex
Bit-mapped register:
+002
1
0
0
Grant Remote Digital Loop-back test request.
&T4
2
2
Deny Remote Digital Loop-back test request. (Default)
&T5*
S15=
bit
dec
hex
Bit-mapped register.
+066