ZyXEL omni.net Plus User Guide - Page 40

Table 4-9 Supported Commands per TIA PN2388 8/20/90, Table 4-10 Class 2 Command Responses

Page 40 highlights

Omni 56K Plus Series User's Guide Table 4-9 Supported Commands (per TIA PN2388 8/20/90) COMMAND DESCRIPTION VALUE Page bad; procedure interrupt requested. n=4 Page good; procedure interrupt requested. n=5 +FREL=n Phase C received EOL alignment: The EOL patterns are bit aligned as received. n=0 The last received bits of EOL patterns are byte aligned by the DCE, n=1 with necessary zero fill bits inserted. Refer to TIA PN-2388 for details. +FREV? Request the DCE revision identification. +FSPL=n "Enable polling" command: Disable polling. n=0 Enable polling. n=1 All other +F commands are not supported, but the modem will respond OK. In many cases this means "don't care". Table 4-10 Class 2 Command Responses RESPONSE +FCFR +FCIG:"string" +FCON +FCSI:"string" +FDCS:vr,br,wd,ln,df,ec,bf,st VALUE +FDIS:vr,br,wd,ln,df,ec,bf,st +FDTC:vr,br,wd,ln,df,ec,bf,st +FET:n +FHNG:n +FNSC:"HEX string" +FNSF:"HEX string" +FNSS:"HEX string" n=00 n=10 n=20 n=40 n=50 n=70 n=90 n=100 FUNCTION AND DESCRIPTION Confirmation . Report remote ID response CIG. Facsimile connection response. Report remote ID response CSI. Report session parameters response; refer to +FDCC=.... command. Report session negotiation parameters response; refer to +FDCC=.... command. Report remote capabilities response; refer to +FDCC=.... command. Post page message response; refer to the +FET=n command. Call termination status response. Normal and proper end of connection. Transmit error on phase A hang up code. Transmit error on phase B hang up code. Transmit error on phase C hang up code. Transmit error on phase D hang up code. Receive error on phase B hang up code. Receive error on phase C hang up code. Receive error on phase D hang up code. Report the non-standard facilities command frame. Report the non-standard facilities frame response. Report the non-standard setup frame response. 4-12 Command Sets

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
4-12
Command Sets
Table 4-9 Supported Commands (per TIA PN2388 8/20/90)
COMMAND
DESCRIPTION
VALUE
Page bad; procedure interrupt requested.
n=4
Page good; procedure interrupt requested.
n=5
+FREL=n
Phase C received EOL alignment:
The EOL patterns are bit aligned as received.
n=0
The last received bits of EOL patterns are byte aligned by the DCE,
with necessary zero fill bits inserted. Refer to TIA PN-2388 for details.
n=1
+FREV?
Request the DCE revision identification.
+FSPL=n
"Enable polling" command:
Disable polling.
n=0
Enable polling.
n=1
All other +F commands are not supported, but the modem will respond OK. In many cases this means
"don't care".
Table 4-10 Class 2 Command Responses
RESPONSE
VALUE
FUNCTION AND DESCRIPTION
+FCFR
Confirmation .
+FCIG:"string"
Report remote ID response CIG.
+FCON
Facsimile connection response.
+FCSI:"string"
Report remote ID response CSI.
+FDCS:vr,br,wd,ln,df,ec,bf,st
Report session parameters response; refer to
+FDCC=
....
command.
+FDIS:vr,br,wd,ln,df,ec,bf,st
Report session negotiation parameters response; refer to
+FDCC=
....
command.
+FDTC:vr,br,wd,ln,df,ec,bf,st
Report remote capabilities response; refer to
+FDCC=
....
command.
+FET:n
Post page message response; refer to the +FET=n command.
Call termination status response.
n=00
Normal and proper end of connection.
n=10
Transmit error on phase A hang up code.
n=20
Transmit error on phase B hang up code.
n=40
Transmit error on phase C hang up code.
n=50
Transmit error on phase D hang up code.
n=70
Receive error on phase B hang up code.
n=90
Receive error on phase C hang up code.
+FHNG:n
n=100
Receive error on phase D hang up code.
+FNSC:"HEX string"
Report the non-standard facilities command frame.
+FNSF:"HEX string"
Report the non-standard facilities frame response.
+FNSS:"HEX string"
Report the non-standard setup frame response.