ZyXEL omni.net Plus User Guide - Page 37

Service Class 2 Commands, Table 4-7 The Value of <MOD> Parameters, Table 4-8 Command Syntax

Page 37 highlights

Omni 56K Plus Series User's Guide VALUE 74 96 97 98 121 122 145 146 Table 4-7 The Value of Parameters MODULATION V.17 short train V.29 V.17 V.17 short train V.17 V.17 short train V.17 V.17 short train SPEED 7200 9600 9600 9600 12000 12000 14400 14400 4.2.2 Service Class 2 Commands The following Class 2 commands are supported and implemented as per TIA PN2388 (8/20/90): Table 4-8 Command Syntax COMMAND SYNTAX += +=? +? DESCRIPTION Execute a command or set a parameter. Read permissible settings. Read current setting. Table 4-9 Supported Commands (per TIA PN2388 8/20/90) COMMAND DESCRIPTION +FAA=n Auto-answer mode parameter: Answer as set by +FCLASS. DCE answers and auto-determines type. +FBADLIN= Bad line threshold (number of consecutive bad lines for a bad page parameter): Determine if Copy Quality OK on the T.30 flow chart. =0 to 255; a value of 0 implies that error checking is disabled. +FBOR=n Phase C data bit order: Select direct bit order. Select reversed bit order in receiving mode for phase C data. +FBUF? Buffer size; read only parameter: Allow DTE to determine the characteristics of the DCE's buffer size. +FCIG="string" Local fax station ID string, for polling Rx. +FCLASS=n Service class selection: Refer to +FCLASS Class 1 command in previous section. +FCON DCE responds fax connection. +FCQ=n Copy quality check capability parameter No copy quality check capability. VALUE n=0 n=1 0-255 n=0 n=1 n=0 Command Sets 4-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
Command Sets
4-9
Table 4-7 The Value of <MOD> Parameters
VALUE
MODULATION
SPEED
74
V.17 short train
7200
96
V.29
9600
97
V.17
9600
98
V.17 short train
9600
121
V.17
12000
122
V.17 short train
12000
145
V.17
14400
146
V.17 short train
14400
4.2.2 Service Class 2 Commands
The following Class 2 commands are supported and implemented as per TIA PN2388 (8/20/90):
Table 4-8 Command Syntax
COMMAND SYNTAX
DESCRIPTION
+<command>=<value>
Execute a command or set a parameter.
+<command>=?
Read permissible settings.
+<command>?
Read current setting.
Table 4-9 Supported Commands (per TIA PN2388 8/20/90)
COMMAND
DESCRIPTION
VALUE
+FAA=
n
Auto-answer mode parameter:
Answer as set by +FCLASS.
n=0
DCE answers and auto-determines type.
n=1
+FBADLIN=
<value>
Bad line threshold (number of consecutive bad lines for a bad page
parameter):
Determine if Copy Quality OK on the T.30 flow chart. <value>=0 to
255; a value of 0 implies that error checking is disabled.
0-255
+FBOR=
n
Phase C data bit order:
Select direct bit order.
n=0
Select reversed bit order in receiving mode for phase C data.
n=1
+FBUF?
Buffer size; read only parameter:
Allow DTE to determine the characteristics of the DCE’s buffer size.
+FCIG=
"string"
Local fax station ID string, for polling Rx.
+FCLASS=
n
Service class selection: Refer to +FCLASS Class 1 command in
previous section.
+FCON
DCE responds fax connection.
+FCQ=
n
Copy quality check capability parameter
No copy quality check capability.
n=0