ZyXEL omni.net Plus User Guide - Page 32

Table 4-3 Extended AT& Command Sets

Page 32 highlights

Omni 56K Plus Series User's Guide COMMAND &Gn &Hn &Kn &Nn Table 4-3 Extended AT& Command Sets OPTIONS &G0 * &G2 &H0 &H3 * &H4 &K0 &K1 &K2 &K3 &K4 * &K5 &N0 * &N3 &N4 &N5 &N12 &N13 &N14 &N15 &N16 &N17 &N18 &N19 &N24 &N25 &N60 &N61 &N62 &N63 &N64 FUNCTION & DESCRIPTION Guard tone options No guard tone (within USA, Canada). 1800 Hz guard tone. Data flow control, DTE/DCE. Flow control disabled. Hardware (CTS/RTS) flow control. Software (XON/XOFF) flow control. Modem error control and data compression. No error control.(Same as AT&K) MNP4 (See also S41.0).(include MNP3) MNP4+MNP5 (See also S38.5, S41.0). V.42+MNP4. V.42+V.42bis, compatible with &K2 (See also S38.5). V.42+V.44 Modem link mode options (DCE/DCE). (See also S43.7, S48.1) Multi-Auto, auto negotiate highest possible link rate: V.92, V.90, V.34bis, V.32bis, V.32, V.22bis, V.22 and Bell 212A, G3 Fax V.17/V.29/V.27ter. V.32 9600T/9600/7200T/4800 V.32 9600/7200/4800 V.32 4800 V.23 1200/75 V.23 600/75 V.22bis 2400/1200 V.22 1200 V.21 300 V.32bis 14400/12000/9600/7200/4800 V.32bis 12000/9600/7200/4800 V.32bis 7200/4800 BELL 212A 1200 BELL 103 300 V.34 33600 V.34 31200 V.34 28800 V.34 26400 V.34 24000 REF. S28.4-5 S27.3-5 S27.0-2 S19 4-4 Command Sets

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
4-4
Command Sets
Table 4-3 Extended AT& Command Sets
COMMAND
OPTIONS
FUNCTION & DESCRIPTION
REF.
&Gn
Guard tone options
S28.4-5
&G0
*
No guard tone (within USA, Canada).
&G2
1800 Hz guard tone.
&Hn
Data flow control, DTE/DCE.
S27.3-5
&H0
Flow control disabled.
&H3
*
Hardware (CTS/RTS) flow control.
&H4
Software (XON/XOFF) flow control.
&Kn
Modem error control and data compression.
S27.0-2
&K0
No error control.(Same as AT&K)
&K1
MNP4 (See also S41.0).(include MNP3)
&K2
MNP4+MNP5 (See also S38.5, S41.0).
&K3
V.42+MNP4.
&K4
*
V.42+V.42bis, compatible with &K2 (See also S38.5).
&K5
V.42+V.44
&Nn
Modem link mode options (DCE/DCE). (See also S43.7, S48.1)
S19
&N0
*
Multi-Auto, auto negotiate highest possible link rate: V.92, V.90,
V.34bis, V.32bis, V.32, V.22bis, V.22 and Bell 212A, G3 Fax
V.17/V.29/V.27ter.
&N3
V.32 9600T/9600/7200T/4800
&N4
V.32 9600/7200/4800
&N5
V.32 4800
&N12
V.23 1200/75
&N13
V.23 600/75
&N14
V.22bis 2400/1200
&N15
V.22 1200
&N16
V.21 300
&N17
V.32bis 14400/12000/9600/7200/4800
&N18
V.32bis 12000/9600/7200/4800
&N19
V.32bis 7200/4800
&N24
BELL 212A 1200
&N25
BELL 103 300
&N60
V.34 33600
&N61
V.34 31200
&N62
V.34 28800
&N63
V.34 26400
&N64
V.34 24000