ZyXEL omni.net Plus User Guide - Page 39

COMMAND, DESCRIPTION, VALUE, DTE Phase C response time-out

Page 39 highlights

Omni 56K Plus Series User's Guide COMMAND Table 4-9 Supported Commands (per TIA PN2388 8/20/90) DESCRIPTION VALUE +FDR +FDT=df,vr,wd, ln +FET=n +FK +FLID="string" +FLO=n +FLPL=n +FMDL? +FMFR? +FMINSP=n +FPHCTO= +FPTS=n Receive phase C data command; initiates document reception. Transmit phase C data command: release the DCE to proceed with negotiation. End of page or document command: More pages; same document. End of document; another document follows. No more pages or documents. Procedure interrupt; another page follows. Procedure interrupt; end of document, another document follows. Procedure interrupt; end of document. Regular fax abort command. Local ID string parameter. Flow control options: No flow control. Set XON/XOFF software flow control. Set CTS/RTS hardware flow control. Document for polling command: The DTE has no document available for polling. Indicate a document available for polling. Request DCE model. Request DCE manufacturer. Minimum phase C speed parameter: 2400 bps. 4800 bps. 7200 bps. 9600 bps. 12000 bps. 14400 bps. DTE Phase C response time-out: Determine how long the DCE will wait for a command after reaching the end of data when transmitting in Phase C. =0 to 255; 100 ms units. Page transfer status Received page good. Page bad; retrain requested. Page good; retrain requested. n=0 n=1 n=2 n=4 n=5 n=6 n=0 n=1 n=2 n=0 n=1 n=0 n=1 n=2 n=3 n=4 n=5 0-255 n=1 n=2 n=3 Command Sets 4-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Omni 56K Plus Series User’s Guide
Command Sets
4-11
Table 4-9 Supported Commands (per TIA PN2388 8/20/90)
COMMAND
DESCRIPTION
VALUE
+FDR
Receive phase C data command; initiates document reception.
+FDT=df,vr,wd, ln
Transmit phase C data command: release the DCE to proceed with
negotiation.
+FET=n
End of page or document command:
More pages; same document.
n=0
End of document; another document follows.
n=1
No more pages or documents.
n=2
Procedure interrupt; another page follows.
n=4
Procedure interrupt; end of document, another document follows.
n=5
Procedure interrupt; end of document.
n=6
+FK
Regular fax abort command.
+FLID="string"
Local ID string parameter.
+FLO=n
Flow control options:
No flow control.
n=0
Set XON/XOFF software flow control.
n=1
Set CTS/RTS hardware flow control.
n=2
+FLPL=n
Document for polling command:
The DTE has no document available for polling.
n=0
Indicate a document
available for polling.
n=1
+FMDL?
Request DCE model.
+FMFR?
Request DCE manufacturer.
+FMINSP=n
Minimum phase C speed parameter:
2400 bps.
n=0
4800 bps.
n=1
7200 bps.
n=2
9600 bps.
n=3
12000 bps.
n=4
14400 bps.
n=5
+FPHCTO=
<value>
DTE Phase C response time-out:
Determine how long the DCE will wait for a command after reaching
the end of data when transmitting in Phase C.
<value>=0 to 255; 100 ms units.
0-255
+FPTS=n
Page transfer status
Received page good.
n=1
Page bad; retrain requested.
n=2
Page good; retrain requested.
n=3