3Ware 9550SXU-12 User Guide - Page 278
Rebuild completed, Incomplete unit detected
UPC - 693494970128
View all 3Ware 9550SXU-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 278 highlights
Troubleshooting To lower the likelihood of getting this error, schedule regular verifications. See Also "Setting Overwrite ECC (Continue on Source Error When Rebuilding)" on page 121. "Scheduling Background Tasks" on page 173 0005 Rebuild completed Event Type Information Cause The 3ware RAID controller has successfully completed a rebuild. The data is now redundant. Action None required. 0006 Incomplete unit detected Event Type Warning Cause The 3ware RAID controller has detected an incomplete unit. An incomplete unit is a unit in which the 3ware RAID controller is unable to detect one or more drives. The drives may be missing, dead, or improperly connected. A unit that is incomplete is also degraded (although a degraded unit can be complete if all drives are still detected, including the failed drive). Action Check hardware connections and reseat the drives. Rescan the controller from 3DM to see if the unit has been restored. If you are able to restore the unit before any data has been written to the unit, a rebuild will not be necessary. If the unit remains incomplete, replace the missing or dead drives and initiate a rebuild. 266 3ware SAS/SATA RAID Software User Guide, Version 9.5.1