3Ware 9550SXU-12 User Guide - Page 303
Battery voltage is too low, Cause, Action, Event Type
UPC - 693494970128
View all 3Ware 9550SXU-12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 303 highlights
Error and Notification Messages Cause The battery pack voltage being monitored by the Battery Backup Unit has risen above the warning threshold. Action The Battery Backup Unit is presently still able to backup the 3ware RAID controller, but you should replace the battery pack if the warning continues. 0047 Battery voltage is too low Event Type Error Cause The battery pack voltage being monitored by the Battery Backup Unit is too low to backup the 3ware RAID controller. You may see this message during a battery capacity test. In this case, it is not a sign of battery failure. You may also see this message if the battery pack is plugged in while the computer is on. This is not advised. Action Replace the battery pack if none of the above causes apply and the warning continues. 0048 Battery voltage is too high Event Type Error Cause The battery pack voltage being monitored by the Battery Backup Unit is too high to backup the 3ware RAID controller. Action The battery pack must be replaced. This may be a fault in the BBU control module. If you get this error, do the following: 1 Turn off the computer and remove the 3ware RAID controller. www.3ware.com 291