Aastra OpenCom X320 User Guide - Page 134
Types of Point-to-Point Connections, 10.2.1 Direct Connection, Please note, L1 sync possible
View all Aastra OpenCom X320 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
PBX Networking Types of Point-to-Point Connections automatically switch the clock source to another port configured as an L1 clock source (if a line fails, for example). Please note: Reciprocal or circular application of the L1 clock is not allowed. Example: In the above case you could reverse the L1 slave/master setting for the connection between PBX 1 and PBX 3. However, if you then activate the setting L1 sync possible for the port of PBX 1, this may cause parts of the PBX network to stop functioning temporarily. When applying the L1 clock of trunk lines, you can assume that the public network is "clock-aligned". So, in the above example, you can connect additional trunk lines to one of the PBXs. 10.2 Types of Point-to-Point Connections There are different types of connection available for an point-to-point connection between two PBXs, depending on the distance between them. 10.2.1 Direct Connection This type of ISDN point-to-point connection joins the two systems directly to each other using a crossover twisted-pair cable. An S0 connection can be used for distances up to 1,000 metres. Normally one PBX is the protocol master for all three layers, and the other PBX is the protocol slave for all three layers. PBX 1 L1 master L2 master L3 master Direct connection PBX 2 L1 slave L2 slave L3 slave ■ Use the RJ45 jacks on one of the external S0 ports for an S0 connection between two OpenCom X320s. You can use the corresponding pressure ter- minals for S0 ports on interface cards. 132