Aastra OpenCom X320 User Guide - Page 51

Actor, PBX Configuration, Ports, Change, Doorstation 2-wire, Actor, Doorbell

Page 51 highlights

Installation Port assignment, termination, cable length be connected to any a/b port via the "DoorLine M06" module. The "DoorLine" module also provides the actor for the door opener contact. Please observe the following points when connecting the door intercom system: ■ The door intercom system and the "DoorLine" module should be set to their factory settings. ■ In the PBX Configuration: Ports: a/b: Change menu in the Configurator, select Doorstation 2-wire as the Type. Dectivate the Actor option if you want to use the OpenCom X320 actor port instead of the "DoorLine" relay to open the door. The "DoorLine" actor can only be used if the speech channel is open at the same time. The internal actor can be used at any time. ■ The "DoorLine" intercom system has a number of bell keys to which you can assign various call numbers in the Configurator under the menu item PBX Configuration: Ports: Doorbell. ■ You can call the"DoorLine" intercom system by using the code procedure *102. ■ The "DoorLine" can be connected to any a/b port, but you can only operate one "DoorLine" intercom system using OpenCom X320. You will find more detailed information on installing and configuring the "DoorLine" intercom system in the product's user guide. The intercom system should only be connected by a skilled electrician, because sensor/actor contacts must be connected to the "DoorLine" module. Tip: Analogue trunk connections can be made using an additional interface card. You will find an explanation of the interface card in the guide to the "M100-AT4 interface card. 3.9.4 Actor OpenCom X320 can be connected to a door intercom system of the "DoorLine". This intercom system is connected to one of OpenCom X320'sa/b ports via the "DoorLine" module (see Intercom system (for a/b) starting on page 48). 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192

Installation
Port assignment, termination, cable length
49
be connected to any a/b port via the “DoorLine M06” module. The “DoorLine”
module also provides the actor for the door opener contact.
Please observe the following points when connecting the door intercom system:
The door intercom system and the “DoorLine” module should be set to their
factory settings.
In the
PBX Configuration
:
Ports
:
a/b
:
Change
menu in the Configurator,
select
Doorstation 2-wire
as the
Type
. Dectivate the
Actor
option if you want
to use the OpenCom X320 actor port instead of the “DoorLine” relay to open
the door. The “DoorLine” actor can only be used if the speech channel is open
at the same time. The internal actor can be used at any time.
The “DoorLine” intercom system has a number of bell keys to which you can
assign various call numbers in the Configurator under the menu item
PBX Configuration
:
Ports
:
Doorbell
.
You can call the“DoorLine” intercom system by using the code procedure
*102
.
The “DoorLine” can be connected to any a/b port, but you can only operate
one “DoorLine” intercom system using OpenCom X320.
You will find more detailed information on installing and configuring the
“DoorLine” intercom system in the product’s user guide.
The intercom system should only be connected by a skilled electrician, because
sensor/actor contacts must be connected to the “DoorLine” module.
Tip:
Analogue trunk connections can be made using an additional
interface card. You will find an explanation of the interface
card in the guide to the “M100-AT4 interface card.
3.9.4
Actor
OpenCom X320 can be connected to a door intercom system of the “DoorLine”.
This intercom system is connected to one of OpenCom X320’sa/b ports via the
“DoorLine” module (see
Intercom system (for a/b)
starting on page 48
)
.