88 5 System troubleshooting Component troubleshooting Listed below are specific problems that may arise during the use of your server and their possible solutions. Power indicator does not light. Do the following: • Make sure the power supply module is properly installed. • Make sure the power cord is connected correctly. • Make sure that the wall outlet has power. Test it by plugging another device. • Make sure the power indicator on the front panel is lit up green. • Remove all add-in cards and see if the system boots up. If reboot is successful, install the cards back in one at a time with a reboot between each addition to determine if one of them is causing the problem. • Make sure that you have correctly installed system compliant memory modules, and that the system DIMM population guidelines were observed. • Make sure that you have installed a system compliant processor. FDD activity indicator does not light. Do the following: • Make sure the FDD data and power cables are properly connected. • Check that relevant switches and jumpers for the FDD are set correctly. • Check that the FDD is properly configured.