Asus AP3000 Hardware Reference - Page 31
Front Cooling Fan Control Board, Hard Disk Drive Message Board
View all Asus AP3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
IV. Hardware Setup Connects to the SCSI Back plane Board IV. Hardware Setup Front Cooling Fans 3-pin Fan Header Pin 1 3-pin Fan Header 8 1 LED Board Header (connects to the LED 16 9 board through a ribbon cable) Front Cooling Fan Control Board A cable connects the front cooling fan control board and the hard disk drive message board. Orient the red markings on each end of the cable to pin 1. Pin 1 8 1 16 9 First Set of LEDs Green Red Yellow Fifth Set of LEDs Hard Disk Drive Message Board Orient the red markings on the other end of the cable to pin 1. If the fifth set of LEDs fails, it can be indicating a faulty front cooling fan control board condition. Remove the control board and send it back to your dealer. Message LED Description Green: Power LED Yellow: Hard Disk Access LED Red: Hard Disk Status LED Power LED off on on on on fast flash fast flash Status LED off off on fast flash slow flash on fast flash Description Power subsystem OK and ready for hard drive insertion Hard disk drive is ready for operation Hard disk drive failure (*) RAID is rebuilding (*) Hot-spare hard disk drive ready (*) Hard disk drive failure/short circuits Fan failure * Must be provided by RAID controller's SAF-TE function. AP 3000 Hardware Reference Guide 31