Asus KFN32-D SLI SAS User Guide - Page 82

Chipset

Page 82 highlights

4.4.4 Chipset The Chipset menu allows you to change the advanced chipset settings. Select an item then press to display the sub-menu. Advanced Chipset Settings WARNING: Setting wrong values in below sections may cause system to malfunction. NorthBridge Configuration SouthBridge/MCP55 Configuration Hyper Transport Configuration I055 Bridge Configuration Intel PCI-X Hub Configuration Options for NB. NorthBridge Configuration The NorthBridge Configuration menu allows you to change the Northbridge settings. NorthBridge Chipset Configuration Memory Configuration ECC Configuration Power Down Control Alternate VID [Auto] [0.850 V] Node0 Size of DIMM #0 Size of DIM #1 Size of DIMM #2 Size of DIM #3 Size of DIM #4 Size of DIMM #5 Size of DIM #6 Size of DIM #7 : Non-Presence : Non-Presence : Non-Presence : Non-Presence : Non-Presence : Non-Presence : Non-Presence : Non-Presence Node1 Size of DIMM #0 : Non-Presence Select Screen Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit Memory Configuration The memory configuration menu allows you to change the memory settings. Memory Configuration Memclock Mode MCT Timing Mode Bank Interleaving Enable Clock to All DIMMS DQS Signal Training Control MemClk Tristate C3/ATLVID CS Sparing Enable Memory Hole Remapping [Auto] [Auto] [Auto] [Disabled] [Enabled] [Disabled] [Disabled] [Enabled] 4-22 Select the DRAM Frequency program method. If Auto, the DRAM speed will be based on SPDs. If Limit, the DRAM speed will not exceed the specific value. If Manual, the DRAM will be programmed regardless. Select Screen Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit Chapter 4: BIOS setup

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

4-22
Chapter 4: BIOS setup
4.4.4 Chipset
The Chipset menu allows you to change the advanced chipset settings.
Select an item then press <Enter> to display the sub-menu.
NorthBridge Configuration
The NorthBridge Configuration menu allows you to change the Northbridge
settings.
Memory Configuration
The memory configuration menu allows you to change the memory
settings.
Memory Configuration
Memclock Mode
[Auto]
MCT Timing Mode
[Auto]
Bank Interleaving
[Auto]
Enable Clock to All DIMMS
[Disabled]
DQS Signal Training Control
[Enabled]
MemClk Tristate C3/ATLVID
[Disabled]
CS Sparing Enable
[Disabled]
Memory Hole Remapping
[Enabled]
Select the DRAM
Frequency program
method. If Auto,
the DRAM speed will
be based on SPDs.
If Limit, the DRAM
speed will not exceed
the specific value.
If Manual, the DRAM
will be programmed
regardless.
NorthBridge Configuration
SouthBridge/MCP55 Configuration
Hyper Transport Configuration
I055 Bridge Configuration
Intel PCI-X Hub Configuration
Options for NB.
Advanced Chipset Settings
WARNING: Setting wrong values in below sections
may cause system to malfunction.
Select Screen
Select Item
+-
Change Option
F1
General Help
F10
Save and Exit
ESC
Exit
NorthBridge Chipset Configuration
Memory Configuration
ECC Configuration
Power Down Control
[Auto]
Alternate VID
[0.850 V]
Node0
Size of DIMM #0
:
Non-Presence
Size of DIM #1
:
Non-Presence
Size of DIMM #2
:
Non-Presence
Size of DIM #3
:
Non-Presence
Size of DIM #4
:
Non-Presence
Size of DIMM #5
:
Non-Presence
Size of DIM #6
:
Non-Presence
Size of DIM #7
:
Non-Presence
Node1
Size of DIMM #0
:
Non-Presence