Bosch NWD-495V03-20P Operating Instructions - Page 23
Attach the mounting plate, Make the connections
View all Bosch NWD-495V03-20P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
FlexiDomeDN IP Mounting the unit | en 23 3.1 Attach the mounting plate 1. Use the mounting plate as a drilling temple to drill three holes in the mounting surface. 2. Use the supplied plugs and screws to attach the mounting plate to the surface. 3. With a rear connection, leave the cap in place. With a side connection: a. remove the cap covering the side entrance; b. attach a 22 mm / ½ inch (PG16) gland conduit to the mounting plate. 3.2 Make the connections To connect the wiring to the camera, use the metal mounting wire to hold the camera during installation on a ceiling. Make the power and network connection from inside the connection box. Suspension wire Connection box Fig. 3.3 Preparation 1. Pull out the connection box from the camera encasing. 2. To open the connection box, loosen the Phillips screws, and open the cover flips. CAUTION! ! Never supply power via the Ethernet connection (PoE) when power is supplied via the power connector. Bosch Security Systems Operating Instructions V 1.0 | 2006.12