26 en | Camera set-up FlexiDomeDN IP - To obtain a horizontal horizon (for tilted ceilings or sidewall mounting), rotate the base of the lens as necessary to align the picture shown on the monitor. Do not rotate more than 340°. CAUTION! The CCD image sensors are highly sensitive and require special care for proper performance and extended ! lifetime. Do not expose them to direct sunlight or bright spotlights in operating and non-operating conditions. Avoid bright lights in the field of view of the camera. 4.2 Focal length and focus Before adjusting, place the adjustment cap on the lens to ensure that the image sharpness is the same as when the dome is in place. 1. To set the field of view of the varifocal lens, loosen the focal length screw and turn the mechanism until the required view is displayed on the monitor. (Image goes out of focus.) 2. Focus the image on the monitor by loosening the focus screw and turning the mechanism until the image is in focus. 3. Readjust the focal length if necessary. 4. Repeat these two adjustments until the desired view is in focus. 5. Tighten both screws. 6. Remove the adjustment cap from the lens. 4.3 Basic settings The camera normally provides an optimal picture without the need for further adjustments. The camera has an Installer menu in which basic installation settings (IP address) can be accessed. Five keys, located on the side panel, are used for navigating through the basic set-up menu. V 1.0 | 2006.12 Operating Instructions Bosch Security Systems