WSW12 (Signal detection condition setting) Selector No. Function 1 Min. OFF time length of calling 2 signal (Ci) 3 Max. OFF time length of calling 4 signal (Ci) 5 Detecting time setting 6 7 Delay 8 Not used. Setting and Specifications No. 1 2 00 : 01 : 10 : 11 : 300 ms 500 ms 700 ms 900 ms No. 3 4 00 : 01 : 10 : 11 : No. 5 6 00 : 01 : 10 : 11 : 0: Yes 6 sec. 7 sec. 9 sec. 11 sec. 800 ms (1000 ms*) 200 ms 250 ms 150 ms 1: No * 1000 ms in Chinese or Hong Kong versions. • Selectors 1 through 4: Min. and max. OFF time length of calling signal (Ci) If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the Ci signal as OFF. • Selectors 5 and 6: Detecting time setting These selectors set the time length required to make the equipment acknowledge itself to be called. That is, if the equipment continuously detects calling signals with the frequency set by selectors 1 through 4 of WSW14 during the time length set by these selectors 5 and 6, it acknowledges the call. • Selector 7: Delay Setting this selector to "0" allows the equipment to insert a 900 ms WAIT after acknowledgement of the call until the equipment turns on the CML relay to start receiving operation.