Brother International FAX-170 Service Manual - Page 122
Attenuator
View all Brother International FAX-170 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
WSW24 (TAD setting 2) Selector No. Function 1 Maximum OGM recording time 2 Setting and Specifications No. 1 2 00 : 01 : 10 : 11 : 15 sec. 20 sec. 30 sec. 50 sec. 3 Time length from CML ON to start of pseud ring backtone 4 transmission No. 3 4 00 : 01 : 10 : 11 : 4 sec. 3 sec. 2 sec. 1 sec. 5 Attenuator for playback of ICM/ OGM to the line 8 (Selectable from the range of 0-15 dB) 0: 0 dB 0: 0 dB 0: 0 dB 0: 0 dB 1: 8 dB 1: 4 dB 1: 2 dB 1: 1 dB • Selectors 1 and 2: Maximum OGM recording time (For those models equipped with a built-in TAD) These selectors set the allowable maximum recording time for an OGM. • Selectors 3 and 4: Time length from CML ON to start of pseud ring backtone transmission These selectors set the length of time from CML-ON up to the start of pseud ring backtone transmission. In those versions which have an OGM facility instead of pseud ring backtone, these selectors set the length of time from CML-ON up to the start of OGM transmission. • Selectors 5 through 8: Attenuator for playback of ICM1OGM to the line (For those models equipped with a built-in TAD) Setting two or more selectors to "1" produces addition of attenuation assigned to each selector. This setting will not be limited by selector 8 of WSW23.